Temperature reading adjustment
Allows changing the internal thermostat sensor calibration. This function works only when “R”
is not displayed after the inside temperature on the main screen. Sensors showing an “R
indicate the system is using remote sensors located in the air conditioner and they cannot be
adjusted from the thermostat.
Temperature Gap
This sets the difference in temperature before an action will occur. For example, if the set
point is 75° (24°C) and it goes up 1°, the system is in cooling and the gap is set for 1°, the
thermostat will start a cooling cycle. Setting the gap larger will force the thermostat to see 2, 3, or 4
degrees before starting a cycle. This is helpful in preventing short cycling of the heating or cooling
systems. Note: Not available on all thermostat models
Measurement units
Measurement units are labeled Celsius and Fahrenheit for simplicity. Set for Celsius
to use metric units.
Touchscreen Calibrate
This forces a calibrate screen to appear to allow the user to set the touch points on the
screen. Use a blunt pencil or similar implement to touch the four corner markers as they
appear. Use the three diagonal markers to test the calibration. If the circles overlap even a little it is
sufficient to give good touch results.
Restart
The restart icon allows restarting the thermostat as if you powered it off and on again. The
Micro-Air logo will display followed by the main screen. This option can help recover from
certain problems like a lost WIFI connection.
Reset All
This option resets certain settings in the thermostat. Some thermostats offer options to reset
different parts of the memory to factory settings.
Switches
This option varies by thermostat. Some display the settings provided by the remote dip switches
on the control board. Others allow setting some factory options like heating modes. Please see
the Thermostat Setup section to determine actions needed to set up your thermostat.
Generator start
Remote gGenerator start is an option found on some thermostats. Set the icon for the color
version to turn on the generator when a cooling or heating cycle is needed. Set it for gray
when it is not needed.