EasyTouch RV 353 Manual

11
©2022 Micro-Air Corp May 10, 2022, revision 1.1
Dry Mode
This mode attempts to remove humidity from the space using a set algorithm. Table 7 describes
this algorithm.
Environment
Cycle Operation
Fan Operation
Inside Setpoint
Compressor ON for 10 minutes
and OFF for 6 minutes
Always Low
Inside > Setpoint
Compressor ON
Table 7 - Dry Mode Operation
Auto Modes
This mode will automatically switch between
heating and cooling cycles as needed. Their operation will
be the same as their “only” mode counterparts described
earlier in the Operational Modes section. Auto modes will
have their own “dual” set-points that are separate heating
and cooling set-points. No heating or cooling cycles will
occur when the inside temperature is between the set-
points.
This can be useful when setting a higher day-time
cooling temperature and lower night-time heating
temperature. It can also be used to control the
temperature extremes when you are away from the RV.
Figure 2 shows how the main screen will look in auto mode.
Note: Auto mode is subject to Gap operations. See section
Temperature Gap (Hysteresis) for more details.
(1) Auto Mode Set-Points
Press the set-points to toggle between which set-point you
have selected. A blue square will show around the one you
have selected. The upper set-point is for cooling and the
lower set-point is for heating.
(2) Set-Point Adjustment
Use the up and down arrows to change the selected set-point value.
Figure 2 - Auto Mode Main Screen
Auto Mode