EasyTouch RV 351 Manual
12 
©2022 Micro-Air Corp    June 15, 2022, revision 1.5 
Gas Heat Override 
  This function is handled by the control board and not the thermostat. It will activate when the 
outside temperature falls below the minimum heat pump operating temperature if available on the 
system.  
Smart device application only features 
Reset device 
  This Bluetooth only feature allows resetting the display just as if you removed and restored 
power. 
Calibrate Touchscreen 
  It is normally not necessary to recalibrate the touchscreen. This selection prompts the user to 
press the four corners of the display then test the calibration using three diagonal marks. This feature is 
only available from Bluetooth since being at the thermostat is required. 
Check for updates 
  Checks to see if any updates are available for the thermostat. The smart device application must 
have internet and the thermostat must be connected to WIFI with a green WIFI symbol. Tap Check for 
Updates and follow the prompts. 
Notifications 
  Notifications provide a way for the thermostat to communicate back to a smart device like a 
tablet or phone. These notifications are indications of the temperature exceeding a set limit. Limits are 
set by connecting to the thermostat in the app, selecting the settings gear, and then selecting 
notifications. A minimum and maximum allowed temperature can be set. Table 4 shows an example of 
operation with an 80°F maximum temperature set. Notification will be sent for each degree it rises 
above the maximum temperature. If temperature drops, no notification will be sent unless the 
temperature exceeds the last maximum temperature again (82 in the example). If the temperature 
drops two degrees below the set maximum, (78 in the example) it will again alert for each degree above 
the set maximum. This behavior helps avoid nuisance notifications to your smart device. 
Table 4 
Temperature °F 
Action 
80 
Send first notification 
81 
Send another notification 
82 
Send another notification 
81…79 
Temperature drops, no 
notification 
78 
Max temp resets 