Specifications

Micrel, Inc.
KSZ8895MQ/RQ/FMQ
Advanced Control Registers (Continued)
Use registers 110 and 111 to read or write data to the static MAC address table, VLAN table, dynamic address table,
or the MIB counters.
Address Name Description Mode Default
Register 110 (0x6E): Indirect Access Control 0
75
Reserved Reserved. R/W 000
4 Read High Write Low
1, read cycle.
0, write cycle.
R/W 0
32
Table Select
00 = static mac address table selected.
01 = VLAN table selected.
10 = dynamic address table selected.
11 = MIB counter selected.
R/W 0
10
Indirect Address High Bit 9-8 of indirect address. R/W 00
Register 111 (0x6F): Indirect Access Control 1
70
Indirect Address Low Bit 7-0 of indirect address. R/W 00000000
Note:
Write to Register 111 will actually trigger a command. Read or write access will be decided by bit 4 of Register 110.
March 12, 2014
74
Revision 1.7