Specifications

Micrel, Inc.
KSZ8895MQ/RQ/FMQ
Global Registers (Continued)
Address Name Description Mode Default
5 PLL Power Down
Pll power down enable:
1 = Enable
0 = Disable
R/W 0
4–3 Power Management Mode
Power management mode :
00 = Normal mode (D0)
01 = Energy Detection mode (D2)
10 = soft Power Down mode (D3)
11 = Power Saving mode (D1)
R/W
00
Pin LED[4][0]
strap option.
PD(0): Select
Energy detection
mode
PU(1): (default)
Normal mode
Note: LED[4][0]
has internal pull-
up.
20
Reserved N/A Do not change. RO 000
Register 15 (0x0F): Power Down Management Control 2
7–0 Go_sleep_time[7:0]
When the Energy Detect mode is on, this value is
used to control the minimum period that the no energy
event has to be detected consecutively before the
device enters the low power state. The unit is 20 ms.
The default of go_sleep time is 1.6 seconds (80Dec x
20ms).
R/W 01010000
March 12, 2014
64
Revision 1.7