Specifications

Micrel, Inc.
KSZ8895MQ/RQ/FMQ
RMII Timing
Figure 26. RMII Timing Data Received from RMII
Figure 27. RMII Timing Data Transmitted to RMII
Timing Parameter Description Min. Typ. Max. Unit
t
cyc
Clock cycle 20 ns
t
1
Setup time 4 ns
t
2
Hold time 2 ns
t
od
Output delay 3 14 ns
Table 27. RMII Timing Parameters
March 12, 2014
110
Revision 1.7