MIIM Registers (Continued)
Address Name Description Mode Default
1 Remote Loopback
1, Perform Remote loopback, loop back path as
follows:
Port 1 (PHY ID address 0x1 reg. 1f, bit 1 = ‘1’)
Start: RXP1/RXM1 (port 1)
Loopback: PMD/PMA of port 1’s PHY
End: TXP1/TXM1 (port 1)
Setting PHY ID address 0x2,3,4,5 reg. 1f, bit 1 = ‘1’
will perform remote loopback on port 2, 3, 4, 5.
0, Normal Operation.
R/W 0
0 Reserved N/A RO 0