Instruction manual
T30
-4-
ELECTRICAL SAFETY
Power Supply
Before any maintenance work,
isolate mains plug from power
source.
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Machines marked for 230 volt can also be
operated from a 220 volt supply.
The vacuum cleaner is supplied
from the factory with mains
supply cable which has an
earthed plug. It must only be
connected to an approved
earthed socket.
Mains Plug Replacement
(UK & Ireland only)
Always check the condition of the cable and plug
before starting with your work.
Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorised
Trend Repair Agent or a qualified electrician.
■ Disconnect the plug from the supply.
■ Cut off the plug and dispose of it safely; a
plug with bared copper conductors is
dangerous if engaged in a live socket outlet.
■ Only fit 13 Amperes BS 1363A approved
plugs fitted with a 13 Amp A.S.T.A approved
BS 1362 fuse (1).
■ The cable wire colours, or a letter, will be
marked at the connection points of most
good quality plugs. Attach the wires to their
respective points in the plug (see below left).
Brown is for Live (L) (2), Blue is for Neutral
(N) (3) and Green/Yellow is for earth (4).
■ Before replacing the top cover of the mains
plug ensure that the cable restraint (5) is
holding the outer sheath of the cable firmly
and that the two leads are correctly fixed at
the terminal screws.
For 115V units with a power exceeding 1500w,
we recommend to fit a plug to BS4343 standard.
Never use a light socket. Never
connect the live (L) or neutral
(N) wires to the earth pin
marked E or .
Using an Extension Cable
■ If an extension cable is required, use an
approved triple core extension cable suitable
for the power input of this tool (see technical
data). The minimal conductor size is 1.5mm
2.
■ When using a cable reel, always unwind the
cable completely.
■ Also refer to the table below.
Cable Rating (Amperes)
Voltage 110V 230V
7.5 15A 6A
15 15A 6A
25 20A 6A
30 25A 6A
45 25A 10A
60 25A 15A
Conductor size Cable rating
(mm
2
) (Amperes)
0.75 6
1.00 10
1.50 15
2.50 20
4.00 25
3
5
2
1
13 AMP
4
Cable Length (m)