Specifications

Installation
13
When using DC power, connect the DC cable to the 3-pin DC power connector, BAT. 12V, on the
MICOM-3TS-RDP connector panel. It is recommended to insert a 30A protection fuse in the positive
lead of the battery cable.
When using AC power, connect the AC cable to the AC POWER connector in the connector panel of
the MICOM-3TS-RDP.
Note
You can connect both AC and DC cables to the MICOM-3TS-RDP simultaneously,
so that the battery serves as a backup power source:
If the AC power source fails, the battery is used as the main power source.
When AC power is restored, the power supply trickle-charges the battery.
Completing the Installation
1. Connect the DC and/or AC power cables to the power source and/or battery.
2. Turn on the MICOM-3TS-RDP.
The MICOM-3TS-RDP is now ready to operate.
Removing the Control Head
The control head of the MICOM-3TS-RDP can be removed from the suitcase body, for placement on
a desktop or at any other convenient location, or semi-permanent wall hanging. The control head is
connected to the MICOM-3ST-RDP suitcase with a 5m (17 ft) cable.
Unscrew the four screws at the corners of the control head. The control head can now be removed.
You can use the two holes at the back of the control head to hang the control head on a wall. The
screws for hanging the control head should be 26.4 cm apart.