7
3. CHARGING THE BATTERIES
NEVER ALLOW THE BATTERIES TO RUN COMPLETELY DOWN, recharge them
within a few minutes after the battery indicator starts to blink “0” on the display (see
section 5). Never leave the batteries completely discharged, even if the machine is not
being used.
When charging the batteries, keep the solution tank lifted and make sure the solution
tank is empty before lifting it.
WARNING! When charging the batteries, follow all the instructions provided
with this manual and the battery charger. Trained staff must carry out the
installation and maintenance operations.
WARNING! Fire Danger: Lead acid batteries generate gases that can cause
an explosion. Keep sparks and flames away from batteries. NO SMOKING!
WARNING! To prevent an explosion, charge the batteries only in an area
with good ventilation.
WARNING! Always wear eye protection and protective clothing when
working near batteries.
Turn the key to the OFF position. Connect the DC connector on the charger to the
DC battery connector (1), located in the lower part of the operator’s seat. Connect the
AC charger plug to a receptacle that has the correct voltage and frequency for your
charger. Make sure the receptacle is connected to the electrical ground.
Check the electrolyte level at least every 20 times the batteries are charged. Add only
distilled water if the level is low.
6. Unlock, then lower the solution tank.
7. Reconnect the hose.