3. When the burner lights, continue to keep the red button depressed for 30 seconds, then release.
4. If burner goes out, wait 5 minutes and repeat lighting procedure.
5. When burner lights, open burner valve to ON position, to operate heater. Partially close valve to regulate
heat output.
Note: Adjusting burn rate too low can cause soot. Watch for and avoid a yellow ame.
RELIGHTING INSTRUCTIONS
1. Rotate valve on cylinder clockwise to close it, and wait ve (5)
minutes.
2. Relight following the LIGHTING INSTRUCTIONS.
SHUT-DOWN INSTRUCTIONS
1. Turn Control Knob to the OFF position
2. Rotate valve on cylinder clockwise to close it
WARNING: NEVER ATTEMPT TO SERVICE THIS HEATER WHILE IT IS STILL OPERATING, OR HOT
OR CONNECTED TO THE GAS SUPPLY. SEVERE BURNS CAN RESULT.
VENTILATION
For these heaters, provide a minimum of 2.5 square feet of space for the MH-0080-CM10, or a minimum
of 6 square feet of space for the MH-0200-CM10 by opening a window or door to provide fresh, outside
air. Provide at least 3 square feet of opening for ventilation per 50,000 BTU of rated operation.