Operator`s manual

14 Kerosene Portable Heaters Manual
RESET AFTER LOCKOUT – SAFETY AIR PRESSURE SWITCH
The heater is equipped with a Reset push button. When the heater locks out, the red lamp on the push but-
ton (number 2 below) lights up. In this case push the Reset button (see Troubleshooting) to restart the heater.
The heater is also equipped with an air pressure switch that controls the airow pressure and locks the
heater out in the event of unit overheating. If this occurs, detect and eliminate the cause of overheating be-
fore using the heater again. Have the heater inspected by a qualied technician if required. See point above
for resetting.
SHUT DOWN
Set switch to “OFF” to shut the ame off. The fan will go on rotating for 1 min 45 sec to cool the heater
down. The fan motor will automatically stop at the end of the after cooling time, then the unit can be discon-
nected from mains.
NEVER DISCONNECT THE SUPPLY PLUG TO STOP THE HEATER WHILE IN OPERATION. THE
BIG AMOUNT OF HEAT PRODUCED COULD DAMAGE THE COMPONENTS: ALLOW COOLING
SEQUENCE TO TAKE PLACE.