Operator`s manual

Kerosene Portable Heaters Manual 13
OPERATION
VENTING
Connect the heater to a ue pipe or to a exhaust duct. To get a proper draft (at least 0,1 mbar) in the ue
pipe, the exhaust gas path must rise. Avoid any elbows and bends in the rst part of the ue pipe for at
least 10 ft. For operation of heater in closed rooms without ue refer to the instructions for installation (page
10, #6).
If a remote thermostat is used, set it on maximum temperature.
Turn switch to “ON” position.
Set the desired temperature on room thermostat.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
CAUTION: WHEN THIS HEATER IS CONNECTED TO A FLUE PIPE, THE FLUE PIPE SHALL
TERMINATE IN A VERTICAL SECTION AT LEAST TWO FEET LONG AND SUFFICIENT DRAFT
SHALL BE CREATED TO ASSURE SAFE AND PROPER OPERATION OF THE HEATER. WHERE
BACK DRAFTS MAY OCCUR, A VERTICAL CAP SHOULD BE USED ON THE EXIT FROM THE
FLUE PIPE. HORIZONTAL RUNS OF THE FLUE PIPE SHOULD HAVE A RISE 1 IN 10 AWAY
FROM THE HEATER.