Operator`s manual

Kerosene Portable Heaters Manual 15
WARNING: NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT!
Use only original equipment replacement parts. The use of alternate or third party components can cause
unsafe operating conditions, and will void your warranty.
We suggest following a maintenance schedule as follows:
FUEL TANK:
Flush every 200 hours of operation or as needed. Do
not use water to ush the tank. Use fresh #1-K kero-
sene only.
AIR FILTERS:
The Air Intake Filter should be replaced or washed
with soap and water and dried thoroughly every 500
hours of operation, or less, depending on conditions.
The Output and Lint Filters should be replaced every
500 hours of operation or less, depending on condi-
tions.
FAN BLADES:
Blades should be cleaned at least once per heating
season, depending on conditions. Remove all accu-
mulated dust and dirt with a damp cloth, taking care
not to bend any of the fan blades. Be sure fan blades
are dry before re-starting the heater.
NOZZLES:
Nozzles should be cleaned or replaced at least once per heating season. Contaminated fuel could make
this necessary immediately.
To clean dirt from nozzle, blow compressed air through nozzle front. It may be necessary to soak nozzle
in clean #1-K kerosene to help loosen any particles.
MAINTENANCE
Air Output
Filter
Intake Filte
r
End Filter Cover
Lint Filter
Set Screw
Motor Shaft
Fan Blade
Burner Head
Nozzle
Nozzle Face
Air Line Fitting
Fuel Line Fitting
Burner Head
Screw
Spark Plug
Ignitor Wire
Fuel Line Hose
Air Line Hose