Operating instructions
75D0004 9
MLDV Series Gas Fireplace
The replace must be secured to the oor and/or to framing studs as shown in Figure 6. Use
two () wood screws or masonry/ concrete screws to secure replace to the oor. Use four (4)
screws to attach replace to framing. The side nailing anges are 1/" or 5/8" to accommodate
different wall thickness.
FP1989
install fireplace
Figure 6 -
Secure Fireplace to Floor and
Framing Studs
Framing
Screws
Nailing Flange
Insulation Board
FP1989
Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done
prior to nal nishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL re rating of
Zero) may be used to cover the black painted face of the appliance. It is permissible to bring com-
bustible wall board to the top and side edges of the black painted face. A 300°F minimum adhesive
may be used to attach facing materials to the black surface. If joints between the nished wall and
the replace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or
equivalent) must be used.