Operating instructions
8
75D0004
MLDV Series Gas Fireplace
71” Minimum
Ceiling
12” Max.
Depth
14” Min.
From Opening
6” Min.
to Opening
FP1987
clearances
Figure 4 -
Side Wall and Ceiling Clearances
Figure 5 -
Mantel clearances.
6"
5"
3"
256O"
456O"
45°
356O"
1"
156O"
FP1949
mantel clearances
Fireplace
Opening
Wall
Combustible
Material Area
Side Wall
Combustible
Mantel
8” Max.
10”
Min.
756O”
Min.
156O”
Max.
256M” Max.
FP2916
Mantel Clearance
14”
Min.
12” Max.
3/4"
Marble
Combustible
Breastplate
Figure 5a -
Mantel Clearance with Eyebrow Canopy
When eyebrow canopy is used, minimum clearance to
combustibles is Z\v" maximum out from replace front at 7Z\x"
minimum from opening. Figure 5a. When eyebrow is not used,
clearances to combustibles is 8" maximum out from replace
front at 10" minimum from opening or 1" maximum out from
replace front at 14" minimum from opening. Figure 5
Eyebrow
Canopy