Operating instructions
0
75D0004
MLDV Series Gas Fireplace
1. Locate and cut the vent opening in the wall. For
combustible walls rst frame in opening.
Cut a 1Z\x"H x
10Z\x" W hole through the interior wall.
Cut a 10Z\x"H
x 10Z\x"W square hole through the exterior
wall frame. Figure 25
Hole opening should
be 8Z\x" (16 mm) in diameter.
. The center of the hole should line up with the
center line of the horizontal rigid vent pipe end.
Allow 1/4" minimum rise per foot. Figure 25
1. Locate and cut the vent opening in the wall. For com-
bustible walls rst frame in opening.
Cut a 11Z\x"H x 9Z\x" W
hole through the interior wall.
Cut a 9Z\x"H x 9Z\x"W
square hole through the exterior wall frame. Figure 26
Hole opening should be 7Z\x"
(190 mm) in diameter.
. The center of the hole should line up with the center line
of the horizontal rigid vent pipe end. Allow 1/4" minimum
rise per foot. Figure 26
B\,
B\,
B\,
FP1954
wall framing
10
1
/"
(67 mm)
10
1
/"
(67 mm)
8
1
/"
(16 mm)
Figure 25 -
Exterior Wall Framing Dimensions for 5" x 8"
Combustible
Wall
Noncombustible
Wall
FP1954
FP1954
wall framing
9
1
/"
(41 mm)
9
1
/"
(41 mm)
7
1
/"
(190 mm)
Combustible
Wall
Noncombustible
Wall
FP1954
Figure 26 -
Exterior Wall Framing Dimensions
for 4" x 6
5
/8" or 4" x 7"