Operating instructions

73D4125
5
KSTDV Series Gas Fireplace


This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.


Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.


   
KSTDV500 Nat. #46 #29
KSTDV500 LP #56 #50
Figure 1 -
KSTDV Controls
FP2543
FP2543
kstdv controls
Control Box
Gas Valve
Command
Center

  
    

KSTDV500 Nat. 56,000 37,000 30,000
KSTDV500 LP 56,000 44,000 27,000