Operating instructions


11
DFX & DBX Series Vent Free Fireplaces


 Clearance requirements as detailed in 
section on  of this manual, must be met before securing the heater in place.
To prevent movement, the heater must be secured to the oor or hearth.
1. Open the control access door and remove the screen.
. Remove carton containing the four-log set.
3. To remove the grate and base assembly, take out two () screws as shown in .
4. Lift grate and base assembly out of the rebox.
5. Secure the rebox with two anchoring screws (3/16" x 1Z\v" length) supplied with the replace
system. 
 If the unit is mounted on carpeting, tile or combustible material without the hearth, a metal
or wooden base covering the entire width and depth of the base must be installed.
FP2515
remove grate
Screws
Grate
FP515
Figure 8 -
Remove Grate
FP2516
secure base
Anchor Screws
3/16" x 1Z\v"
FP516
Figure 9 -
Secure Heater to Floor or Hearth