DFX & DBX Series Vent Free Fireplaces
Clearance requirements as detailed in
section on of this manual, must be met before securing the heater in place.
To prevent movement, the heater must be secured to the oor or hearth.
1. Open the control access door and remove the screen.
. Remove carton containing the four-log set.
3. To remove the grate and base assembly, take out two () screws as shown in .
4. Lift grate and base assembly out of the rebox.
5. Secure the rebox with two anchoring screws (3/16" x 1Z\v" length) supplied with the replace
system.
If the unit is mounted on carpeting, tile or combustible material without the hearth, a metal
or wooden base covering the entire width and depth of the base must be installed.
FP2515
remove grate
Screws
Grate
FP515
Figure 8 -
Remove Grate
FP2516
secure base
Anchor Screws
3/16" x 1Z\v"
FP516
Figure 9 -