GENERAL INSTALLATION INFORMATION
ADEQUATE COMBUSTION AND VENTILATION AIR
Thisheater shallnotbe installedin aconned spaceor unusuallytightconstruction unlessprovisions areprovided for
adequate combustion and ventilation air.
TheNationalFuelGasCodedenesaconnedspaceasaspacewhosevolumeislessthan50cubicfeetper1,000BTUper
hour(4.8m3perkw)oftheaggregateinputratingofallappliancesinstalledinthatspace.Anunconnedspaceisdened
asaspacewhosevolumeisnotlessthan50cubicfeetper1,000BTUperhour(4.8m3perkw)oftheaggregateinputrating
ofallappliancesinstalledinthatspace.Roomscommunicatingdirectlywiththespaceinwhichtheappliancesareinstalled,
throughopeningsnotfurnishedwithdoors,areconsideredapartoftheunconnedspace.
UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE…
a) wallsandceilingsexposedtotheoutsideatmospherehaveacontinuouswatervaporretarderwitharatingof1perm(6
x10
11
kgper-pa-sec-m
2
)orlesswithopeningsgasketedorsealed,and
b) weatherstripinghasbeenaddedonopenablewindowsanddoors,and
c) caulkingorsealantareappliedtoareassuchasjointsaroundwindowsanddoorframes;betweensoleplatesanddoors;
betweenwall-ceilingjoints;betweenwallpanels;atpenetrationsforplumbing,electrical,andgaslines;andatother
openings.
CODES
Adheretoalllocalcodesor,intheirabsence,thelatesteditionofTHENATIONALFUELGASCODEANSIZ223.1or
NFPA54 which can be obtained from…
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
or
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
WARNING
Do not install the heater
• where curtains, furniture, clothing, or other
ammable objects are less than 42" from the front
of the heater.
• in high trafc areas.
• in windy or drafty areas.