IMPORTANT SAFETY INFORMATION
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
15. Keep room area clear and free from combustible materi-
als,gasolineandotherammablevaporsandliquids.
16. Unvented gas heaters are a supplemental zone heater.
They are not intended to be a primary heating appli-
ance.
17. Unventedgasheatersemitmoistureintothelivingarea.
Inmosthomesofaverageconstruction,thisdoesnotpose
a problem. In houses of extremely tight construction,
additional mechanical ventilation is recommended.
18. Duringmanufacturing,fabricatingandshipping,various
components of this appliance are treated with certain oils,
lmsorbondingagents.Thesechemicalsarenotharmful
butmayproduceannoyingsmokeandsmellsastheyare
burnedoffduringtheinitialoperationoftheappliance;
possiblycausingheadaches,oreyeorlungirritation.This
is a normal and temporary occurrence.
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximumventilationbyopeningwindowsordoorsto
allowodorstodissipate.Anyodorsremainingafterthis
initialbreak-inperiodwillbeslightandwilldisappear
with continued use.
19. Input ratings are shown in BTU per hour and are for
elevations up to 2,000 feet. For elevations above 2,000
feet,inputratingsshouldbereduced4percentforeach
1,000 feet above sea level. Refer to the National Fuel Gas
Code.
20. Theapplianceanditsappliancemaingasvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressure testingof thatsystem attest pressuresin
excessof1/2psig(3.5kPa).
21. Theappliancemustbeisolatedfromthegassupplypiping
systembyclosingitsequipmentshutoffvalveduringany
pressuretestingofthegassupplypipingsystemattest
pressuresequaltoorlessthan1/2psig(3.5kPa).
22. Do not use this room heater if any part has been under
water.Immediatelycallaqualiedservicetechnicianto
inspect the room heater and to replace any part of the
controlsystemandanygascontrolwhichhasbeenunder
water.
23. Neverburnsolidfuelsinareplacewhereaunvented
room heater is installed.
24. Alwayshaveareplacescreeninplacewhentheappli-
ance is in operation, and unless other provisions for
combustion air are provided, the screen shall have an
opening(s)forinductionofcombustionair.
25. Donotllspacesaroundthereboxwithinsulationor
other materials. These spaces must be maintained to pre-
ventthereboxfromcomingincontactwithcombustible
materials.