Operating instructions
32 33D4051
OPERATING INSTRUCTIONS
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Thisgaslogsetisequippedwithanignitiondevice(piezo)whichautomaticallylightsthepilot.Ifpiezo
ignitordoesnotlightthepilot,SeeinstructionsforMatch Lighting Instructions, page 32.
4. Turngascontrolknobclockwise totheOFFposition,setthethermostattothelowestsettingandturn
ON/OFF switch to OFF position.
5. Wait(5)minutestoclearoutanygas.Thensmellforgas,includingneartheoor.Ifyousmellgas,STOP!
Follow"B"inthesafetyinformationlabel.Ifyoudon'tsmellgas,gotonextstep.
6. FromOFFposition,turnthegascontrolknobcounterclockwise to IGN position. Push in control
knob for 5 seconds.
7. Withthecontrolknobpushedin,pushinandreleasethepiezoignitorbuttontolightthepilot.
8. Continuepushingthecontrolknobinforafurther60secondstopreventtheamedetectorfromshuttingoff
thegaswhiletheprobeiswarmingup.Releasethecontrolknob.
9. Turngascontrolknobcounterclockwise to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
positionoradjustthermostattodesiredsetting.
11. Ifthegaslogswillnotoperate,followtheinstructionsTo Turn Off Gas To Appliance below and call your
servicetechnicianorgassupplier.
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise to OFF position to completely shut off the heater.
2. Ifapplicable:TurnON/OFFswitchtoOFFpositionand/orsetthermostat(ifpresent)tolowestsetting.
3. If applicable: Turn off all electric power to the heater.
Figure 49 - Pilot Figure 50 - Control Knobs Figure 51 - Piezo
WARNING
Wait 30 seconds before readjusting the
heater when the control knob has been
turned down to a lower setting.