Operating instructions

33D4051 27
INSTALLING ROCK WOOL AND CHECKING BURNER FLAME
PLACING ROCK WOOL
24VFSC AND 32VFSC MODELS
Afterinstallinglogs,pullapartdime-sizepiecesofrockwool.Sprinkle
rockwoolevenlyoverburnerports.Washhandsafterinstallingrockwool.
Itchingmayoccur.
WARNING
Use only rock wool provided with log set.
Do not add additional rock wool.
Place rock wool on burner ports only.
Keep air gap between rear log and burner
CLEAN.
Figure 42 - Correct Appearance of Flames
(24VFSC)
Figure 40 - Rockwool Installation
(24VFSC and 32VFSC)
One-piece
Log
Figure 41 - Correct Appearance of Flames
(24DBXC)
Dime Size
Rock Wool
CHECKING BURNER FLAME
24DBXC MODEL
In normaloperationatfullrateafter15minutes,thefollowing
ameappearancesshouldbeobserved:
The ames inside the one-piece log may be yellow. The
amesshouldextendapproximately2"-4"abovethelog.
See Figure 41.
24VFSC AND 32VFSC MODELS
Innormaloperationatfullrateafter15minutes,thefollowing
ameappearancesshouldbeobserved:
Burner will have a random pattern of yellow ames. See
Figures 42 and 43. Thereshouldbeglowingembersinfront
of burner.
NOTE: The front flames and embers will be an
opaque orange color during the burn off time.
Figure 43 - Correct Appearance of Flames
(32VFSC)