Operating instructions

33D4051 23
SKYTECH
OFF
ON
REMOTE
FIREPLACE
REMOTE
Remote Receiver
Velcro Pad
Velcro
®
Pad
ELECTRICAL WIRING (MILLI-VOLT)
CONNECTING REMOTE RECEIVER
THESE INSTRUCTIONS SUPERSEDE THE SECTION ENTITLED “HEARTH MOUNT” IN THE MILLI-VOLT
HAND-HELD REMOTE INSTRUCTIONS SUPPLIED WITH THE REMOTE.
1. Remove bottom louver door.
2. Connect the remote connectors located in the unit.
3. Stick Velcro
®
padswithself-adhesivebackingtobottomofremotereceiverandtooorofcompartmentbehindaccess
panel.
4. AttachremotereceivertoreboxwithVelcro
®
pads. Control switch must face forward.
CHECKING SYSTEM OPERATION
The millivolt system and individual components may be checked with a millivolt meter having a 0-1000 mV range.
Conduct each check shown in chart below by connection meter test leads to terminals as indicated.
A. COMPLETE MILLIVOLT SYSTEM CHECK
(“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should be come
ON)
a. Ifthereadingismorethan100millivoltsandtheautomaticvalvestilldoesnotcomeon,replacethecontrol.
b. Iftheclosedcircuitreading(“A”reading)islessthan100milli-volts,determinecauseforlowreading,proceedto
Section B below.
B. Thermopile Output Reading Check
(“B” Reading - Thermostat contacts OPEN - Main burner OFF)
1. Checkgaspressuretotheunit.Ifgaspressureiswithinminimumandmaximumondataplate,thencheckpilot
voltage,325millivoltsminimum.Iftheminimummilli-voltreadingisnotobtainable,replacepilot.
Figure 32 - Installing Remote Receiver
CHECK
TEST
TO
TEST
CONNECT
METER
LEADS TO
TERMINALS
SWITCH OR
THERMOSTAT
CONTACTS
METER
READING
SHOULD BE
A
COMPLETE
SYSTEM
2 & 3 CLOSED CLOSED
B
THERMOPILE
OUTPUT
1 & 2 OPEN OPEN
NOTICE
Do not place
remote in
combustion
chamber.