Operating instructions

58D6002
5
Unvented Cast Iron Gas Stoves

ON
OFF
ST1164
CSVF controls
Off/Pilot/On Knob
Hi/Lo Knob
Door
Figure 1 -
Cast Iron Stove (Single Door)
Optional Remote
Receiver
Fan Switch
Piezo
Handle
On/Off
Switch
ST1164
ON
OFF
ST1165
VFCS controls
Figure 2 -
Cast Iron Stove (Double Door)
Break-Away
Handle
Store Break-
Away Handle
Here
Optional Fan Switch
Off/Pilot/On Knob
Hi/Lo Knob
Piezo
Optional
Remote
Receiver
On/Off
Switch

Natural Propane (LP)
Regulator Pressure 3.5” w.c. 10.0” w.c.
Pilot Regulator 3.5” w.c. n/a
Max. Gas Inlet Pressure 10.5” w.c. 13.0” w.c.
Min. Gas Inlet Pressure 5.0" w.c. 11.0" w.c.

Max.Input Min. Input
Model Fuel Control BTU/h BTU/h
CSVF20SNV Nat. Millivolt 10,000 6,000
CSVF20SPV LP Millivolt 10,000 6,000
CSVF30SNV Nat. Millivolt 32,000 20,000
CSVF30SPV LP Millivolt 32,000 20,000
VFCS20DNV Nat. Millivolt 10,000 6,000
VFCS20DPV LP Millivolt 10,000 6,000
VFCS30DNV Nat. Millivolt 32,000 20,000
VFCS30DPV LP Millivolt 32,000 20,000

Piezo ignitor allows ignition of the pilot without the use of
matches.

 - All gas to the burner is shut off at
the valve.
 - Valve position to light/maintain a
standing pilot.
 - Valve position to turn burners ON/
OFF with remote switch.
 - Variable position to control flame
height (heat output). Both front and
rear burners are in operation to pro-
vide realistic glow and yellow flame.

The gas log heater is fitted with a specially designed safety
pilot (ODS assembly) light which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be relit when adequate fresh air
is available.

The millivolt gas log pilot is fitted with a millivolt
thermopile generator to provide power for remote
activation.
 An external regulator is required to reduce supply
pressure to a maximum of 10.5" w.c. on Natural Gas sys-
tems operating at higher pressure.
 An external regulator is required to reduce supply
pressure to a maximum of 13.0" w.c. for LP systems.