Operating instructions
20
58D6002
Unvented Cast Iron Gas Stoves
MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS
1. Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot.
If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,”
Page 21.
4. Turn gas control knob clockwise to the OFF position, and turn ON/OFF switch to OFF posi-
tion.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell
gas, STOP! Follow “What to Do if You Smell Gas,” page 27. If you don't smell gas, go to next
step.
6. From OFF position, turn the gas control knob counterclockwise to IGN position. Push in
control knob for 5 seconds. NOTE: If you are running the heater for the first time, it will
be necessary to press in the control knob for 30 seconds to allow air to bleed out of the
gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the
pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the flame detector
from shutting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF
switch to ON position.
11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and
call your service technician or gas supplier.
TO TURN OFF GAS TO HEATER
1. Turn ON/OFF switch to OFF position.
2. Turn control knob clockwise to OFF position to completely shut off the heater.
3. If applicable: Turn off all electric power to the heater.
Pilot
FP2275
ST1178
control cover plate
OFF
ON
ST1179
on off switch
Control Cover Plate for Millivolt
Hi/Lo Control
Ignitor/Pilot
Control
On/Off Switch
(Located on Side of
Stove)
ST1178