CDVSC7 Series CDV7 Series Direct Vent Gas Fireplace Models: Installation and Operating Instructions WARNINGS CDVR33n/pv7;N/PV117;n/pe7;N/PSC117, CDVT33n/Pv7;n/pe7; N/PSC7, CDVR36n/pv7;n/pe7;N/PSC7, CDVT36n/Pv7;n/pe7;N/PSC7, CDVR42n/pv7;n/pe7;N/PSC7, CDVT42n/Pv7;n/pe7;N/PSC7, CDVR47n/pv7;n/pe7;N/PSC7, CDVT47n/Pv7;n/pe7;N/PSC7 If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
CDVSC7 & CDV7 Series Gas Fireplace CONTENTS PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a MHSC fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Important Safety Information..................................... 3 Code Approval.............................................
IMPORTANT SAFETY INFORMATION INSTALLER WARNING Please leave these instructions with the appliance. CDVSC7 & CDV7 Series Gas Fireplace OWNER Please retain these instructions for future reference. • Read this owner’s manual carefully and completely before trying to assemble, operate, • • or service this fireplace. Any change to this fireplace or its controls can be dangerous.
CDVSC7 & CDV7 Series Gas Fireplace 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15.
product features CDVSC7 & CDV7 Series Gas Fireplace product SPECIFICATIONS • This appliance has been certified for use with either • • • • • • • natural or propane gas. See appropriate data plates. This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
CDVSC7 & CDV7 Series Gas Fireplace product features & Gas specifications HIGH ELEVATIONS GAS pressures Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level. Inlet Minimum Inlet Maximum Manifold Pressure For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. Natural 5.5” w.c. 14.0” w.c. 3.5” w.c. Propane (LP) 11.
CDVSC7 & CDV7 Series Gas Fireplace fireplace dimensions & FRAMING G Minimum Rough Opening Depth F 5/8” 1/2” 1/2” or 5/8” 1/2” M O N M 5/8” L P - Minimum Rough Opening Width Minimum Rough Opening Height 156M” 5/8” 1/2” Q E D C L B C H 1/2” 5/8” 15/16” J K I Figure 2 CDVR Series Fireplace Dimensions A NOTE: Models CDVR33SC7 & CDVR33V117 have no standoffs on top of unit.
fireplace dimensions & FRAMING CDVSC7 & CDV7 Series Gas Fireplace H G Minimum Rough Opening Depth I F 5/8” 1/2” 1/2” or 5/8” 1/2” N P O 5/8” N M Q - Minimum Rough Opening Width Minimum Rough Opening Height 156M” 5/8” 1/2” R E D B C 1/2” 5/8” 15/16” Figure 3 CDVT Series Fireplace Dimensions K J A CDVT33(V,E,SC)7 CDVT36 (V,E,SC)7 A 33" (38 mm) 37Z\zn" (941 mm) B 35B\," (905 mm) 38B\," (981 mm) C 31ZZ\zn" (805 mm) 34>\zn" 693011 (878 mm) dims D 27C\zn" (691 mm) 29Z\zn" CDVT7 (738 top
pRE-INSTALLATION INFORMATION Before You Start Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
CDVSC7 & CDV7 Series Gas Fireplace pRE-INSTALLATION INFORMATION Fireplace Location Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
CDVSC7 & CDV7 Series Gas Fireplace CLEARANCES WARNING Clearances to combustibles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. Finish Wall The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
CDVSC7 & CDV7 Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 7. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.
CDVSC7 & CDV7 Series Gas Fireplace WARNING Venting INSTALLATION INFORMATION Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. installation precautions General Venting Consult local building codes before beginning the installation.
CDVSC7 & CDV7 Series Gas Fireplace Venting INSTALLATION INFORMATION General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A D L V E C B V F Figure 8 Termination Locations B Fixed Closed Ope V B B V Fixed Closed Operable B V J A CFM145a V VENT TERMINATION B V rable X AIR SUPPLY INLET X M I V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 US Installations2 CFM145a A = Clearance above grade, veranda, porch, 12” (30 cm)DV Termin Lo
CDVSC7 & CDV7 Series Gas Fireplace Venting INSTALLATION INFORMATION Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min.
CDVSC7 & CDV7 Series Gas Fireplace Venting INSTALLATION INFORMATION Twist Lock Pipes REAR VENT INSTALLATION ONLY: When using twist lock pipe it is not necessary to use sealant on the joints. Install the 4” (102 mm) vent pipe to the appliance inner collar and secure with three (3) stainless steel sheet metal screws. Install the 7” (178 mm) vent pipe to the appliance outer collar. Secure pipe to the rear cover plate using the tabs and three (3) sheet metal screws.
CDVSC7 & CDV7 Series Gas Fireplace Venting INSTALLATION INFORMATION The Vent Graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph, Figure 13, locate the point intersecting with the slanted graph line. 2.
CDVSC7 & CDV7 Series Gas Fireplace Venting installation VENT PIPE CLEARANCES A Minimum 1" Clearance to Combustibles Permitted All Around Flue at Outside Wall A Minimum of 3" Clearance to the Top Is Required Along Horizontal Length until Flue Pipe Penetrates Outside Wall. 3" CDVR Series 1" A Minimum of 3" Clearance to the Top Is Required Along Horizontal Length until Flue Pipe Penetrates Outside Wall.
CDVSC7 & CDV7 Series Gas Fireplace Venting installation Vent Opening for Combustible Walls Rear Wall Vent Application 9B\,” (244 mm) Min. When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance. • Only MHSC venting components are approved to be • • • used in these applications (Refer to ‘Venting Components’ listed for different installation requirements).
CDVSC7 & CDV7 Series Gas Fireplace Venting installation Finish Wall Rise Vent Termination FP1472 Figure 19 There must be a 1/2" rise per foot length Top vent Sidewall Application Figure 17 Side View of Final Unit Location FP2294 FP2294 Rear Wall Vent Installations Side View Vent Termination 1/25/00 djt Flex Vent Pipe Follow Steps 1 and 2 on Page 19. Step 3 Install the 4” (102 mm) flex vent pipe to the appliance collars described in “General Information Assembling Vent Pipes”, Page 12.
CDVSC7 & CDV7 Series Gas Fireplace Venting installation 3 x 90° Elbows 3 x 90° Elbows B A Figure 21 Maximum three (3) 90° elbows per installation 36" (914mm) Max. A + B = 17' (Max.) (5.2m) FP1176 36" (914mm) Max. 7'6" (2.3m) Figure 23 Horizontal Run Reduction FP1178 B 7’ (2.1 m) A 10’ (3 m) FP1177 Figure 22 Maximum horizontal run with no rise • The maximum number of 90° elbows per side wall installation is three (3).
CDVSC7 & CDV7 Series Gas Fireplace Venting installation Vertical Sidewall Installation Twist Lock Pipe Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. Figure 26 (For combustible walls first frame in opening.) NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vent run.
CDVSC7 & CDV7 Series Gas Fireplace Venting installation Step 6 Use appropriate length of pipe sections - telescopic or fixed - and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. 4” Flex Vent Pipe 12" (305mm) Step 7 Guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm).
CDVSC7 & CDV7 Series Gas Fireplace Venting installation BELOW GRADE INSTALLATION When it is not possible to meet the required vent terminal clearances of 12” (305 mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure the sidewall venting clearances are observed.
CDVSC7 & CDV7 Series Gas Fireplace Venting installation • For the minimum height of the vent above the highest point of penetration through the roof refer to Figure 38, Page 26. Max. Height 40’ (12.2 m) Min. Height 8’ (2.4 m) Max. 10’ (3 m) Support Straps Every 3’ (.9 m) Max. Height 40’ (12.2 m) Min. Height 8’ (2.4 m) Max.
CDVSC7 & CDV7 Series Gas Fireplace 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height. Figure 39 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install. If there is a room above ceiling level, fire stop spacer must be installed on both the bottom ad the top side of the ceiling joists. If an attic is above ceiling level an Attic Insulation Shield must be installed.
CDVSC7 & CDV7 Series Gas Fireplace fireplace installation check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
fireplace installation Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION WARNING CDVSC7 & CDV7 Series Gas Fireplace A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the appliance. Figure 41 A listed manual shutoff valve must be installed upstream of the appliance.
CHECK GAS PRESSURE & Electrical installation CDVSC7 & CDV7 Series Gas Fireplace WARNING 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 30" (mm) flex line with manual shutoff valve has been provided with this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
Electrical installation CDVSC7 & CDV7 Series Gas Fireplace A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 43. Do not extend beyond the wall switch wire length provided. WARNING Remote Wall mounted Switch Do not connect wall switch to (110 V) circuit. NOTE: Extended lengths of wire may cause the fireplace not to function properly.
CDVSC7 & CDV7 Series Gas Fireplace Electrical installation WARNING Electronic Pilot Ignition Wiring Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction.
CDVSC7 & CDV7 Series Gas Fireplace Millivolt OPERATING INSTRUCTIONS WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
millivolt OPERATING INSTRUCTIONS CDVSC7 & CDV7 Series Gas Fireplace Lighting pilot for the first time You may check for gas leaks with the following methods only: DANGER • Soap and water solution • An approved leak testing spray • Electronic sniffer Never check for gas leak with open flame! WARNING approved leak testing method If using a soap and water solution to test for leaks, DO NOT spray solution onto control body. NOTE: Remove any excessive pipe compound from the connections.
CDVSC7 & CDV7 Series Gas Fireplace millivolt OPERATING INSTRUCTIONS Lighting burner Depress and turn the knob counterclockwise to the “ON” position. Figure 49. It will take less than four (4) seconds for the burner to ignite. Pilot position OFF RS OFF P Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. Figure 50 Figure 48 On/Off/RS Switch ON Lighting the burner ILOT The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace.
electronic ignition OPERATING INSTRUCTIONS CDVSC7 & CDV7 Series Gas Fireplace for your safety read before lighting WARNING WARNING A. This appliance is equipped with an ignition device (Piezo) which automatically lights the pilot. Do not If you do not follow these instruction try to light the burner by hand. exactly, a fire or explosion may result B. BEFORE OPERATING smell all around the appliance causing property damage, personal area for gas.
CDVSC7 & CDV7 Series Gas Fireplace SIGNATURE COMMAND - CHECK GAS PRESSURE and ELECTRICAL INSTALLATION 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
CDVSC7 & CDV7 Series Gas Fireplace ELECTRICAL INSTALLATION JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box was installed at the factory. 120V AC 3. The junction box cover has a factory installed “romex” style 60Hz strain relief connector.
ELECTRICAL INSTALLATION CDVSC7 & CDV7 Series Gas Fireplace Optional AC Module To Junction Box in Fireplace Pilot { Plug in Connector Optional Blower Optional Light { White Black White Black Optional { White Black Aux. Green Connector Pin To Control Board Input 300 Watt Max.
CDVSC7 & CDV7 Series Gas Fireplace The black and white wires on the AC box wiring harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is important to use the wires marked ‘Blower’ or the control will not work correctly. WARNING WARNING Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
OPTIONAL FAN BLOWER SYSTEMS CDVSC7 & CDV7 Series Gas Fireplace BLOT AUTOMATIC THERMOSTAT BLOWER 120VAC Receptacle Junction Box BLACK GREEN WHITE BLACK WHITE BLACK FP2675 BLACK Speed Control Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes. Figure 58 BLOT Blower Wiring Diagram FK-12 MANUAL BLOWER FP2675 1. This must be done before framing the fireplace.
OPERATING INSTRUCTIONS - SIGNATURE COMMAND CDVSC7 & CDV7 Series Gas Fireplace WARNING for your safety read before lighting If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. BEFORE OPERATING smell all around the appliance area for gas.
CDVSC7 & CDV7 Series Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND OPERATing INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 41. If you do not smell gas, go to next step. 4.
CDVSC7 & CDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FEATURES To Thermopile RF Receiver ON/OFF Command Center To Sparker • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board To Sensor NG/LP Conversion Control Board To Command Center To Stepper Motor • Electronic Ignition • Pilot Lockout safety feature • Electric Power Regeneratio
CDVSC7 & CDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. Intermittent/Standing Pilot Setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot. 2.
CDVSC7 & CDV7 Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below). For memory feature. Pilot Safety Lockout Function 1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens.
glass removal & ROCK WOOL PLACEMENT CDVSC7 & CDV7 Series Gas Fireplace Glass Frame Removal CAUTION 1. Remove upper and lower louvers. 2. Release the clamps on the bottom of the fireplace. Figure 61 3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame. 4. Set glass frame aside. Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear. Glass Frame ! WARNING HOT GLASS WILL CAUSE BURNS.
CDVSC7 & CDV7 Series Gas Fireplace Log placement log placement Figure 63 1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins shown. 2. Place top right log (#2) on the rear log. Rest the right back side of the log in the flat area of the rear log. Place the narrow front end of the log next to the center vertical grate bar. 3. Place the top left log (#3) on the rear log. Nest the forked end of the top left log into the fork or the rear log.
cleaning and maintenance WARNING CDVSC7 & CDV7 Series Gas Fireplace Thermocouple Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Thermopile Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
cleaning and maintenance CDVSC7 & CDV7 Series Gas Fireplace Vent System The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours.
CDVSC7 & CDV7 Series Gas Fireplace troubleshooting Standing Pilot Ignition SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will A. Wire disconnected. not light pilot after repeated triggering of B. Defective ignitor. piezo. C. No gas or low gas pressure. D. No Propane/LPG in tank 2. Pilot will not stay lit A. Defective thermocouple after carefully following lighting instructions. B. Defective valve 3. Pilot burning, valve A.
CDVSC7 & CDV7 Series Gas Fireplace troubleshooting Standing Pilot Ignition SYMPTOM POSSIBLE CAUSE ACTION 4. Frequent pilot outage problem. A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame or too low, causing pilot impingement on thermocouple. safety to drop out 5. The pilot and main burner extinguish while in operation A. Inner vent pipe leaking exhaust gases back into system A. Check for flue product leak. Replace defective pipe section. B.
CDVSC7 & CDV7 Series Gas Fireplace troubleshooting electronic Ignition START 1. Turn gas supply off. 2. Turn ON/OFF switch to “ON” Power to module (24V Normal) NO YES Is there a spark across ignitor sensor gap? NO Check: Line voltage (120VAC) Low voltage transformer (19.5 minimum VAC) ON/OFF switch Wiring connections Unplug ignition lead and check spark at module (24VAC normal). Is spark OK? NO Replace module YES A. Check ignition cable ground wiring, ceramic insulator and gap.
CDVSC7 & CDV7 Series Gas Fireplace troubleshooting SIGNATURE COMMAND SYSTEM OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open B No sparking on the pilot C Sparking doesn’
CDVSC7 & CDV7 Series Gas Fireplace replacement parts firebox components 3 9 2 5 (CDVT Series) 6 6 6 5 (CDVR Series) 1 12 6 4 7,10,11,13 54 69D3011
replacement parts CDVSC7 & CDV7 Series Gas Fireplace firebox components Item Description Qty. CDVR33 CDVT33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standard Features 1. Junction Box Assy 1 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 2. Black Louver 6 54D0246 54D0246 26D0695 26D0695 26D0697 26D0697 26D0699 26D0699 3. Glass Frame Assy 1 69D0238 69D0238 69D0028 69D0028 69D1107 69D1107 69D2105 69D2105 Factory Installed Service Parts 2.
CDVSC7 & CDV7 Series Gas Fireplace replacement parts Standing Pilot — Millivolt control 2I 1 2C 2T 2 5 4 6 3 8 9 7 10 11,12,13,14 693011 CDV millivolt parts 56 69D3011
CDVSC7 & CDV7 Series Gas Fireplace REPLACEMENT PARTS Standing Pilot – Millivolt Control Item 1. 2. 2C. 2I. 2T. 3. 4. 5. 6. 7. 8. 9. 10. 10. Description Qty. CDV33NV7(117) CDV33PV7(117) CDV36NV7 CDV36PV7 CDV42NV7 CDV42PV7 CDV47NV7 CDV47PV7 Gas Valve Assy.
CDVSC7 & CDV7 Series Gas Fireplace REPLACEMENT PARTS ELECTRONIC IGNITION 1 3 2 LO HI 5 6 7 4 9 11 #1 #2 #3 #4 #5 #6 7# 8 10 Item 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Description Qty. CDV33NE7 CDV33PE7 CDV36NE7 CDV36PE7 CDV42NE7 CDV42PE7 CDV47NE1 CDV47PE7 Gas Valve Assy.
CDVSC7 & CDV7 Series Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 1 2 4 3 5 6 8 7 12 13,14,15,16,17 9 20 693011 cdvrt7 SC parts 69D3011 59
CDVSC7 & CDV7 Series Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM Item Description Qty. CDVR33 CDVR33 CDVT33 CDVT33 CDV(R,T)36 CDV(R,T)36 CDV(R,T)42/47 CDV(R,T)42/47 NSC117 PSC117 NSC7 PSC7 NSC7 PSC7 NSC7 PSC7 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Gas Valve Assy.
CDVSC7 & CDV7 Series Gas Fireplace REPLACEMENT PARTS logs 3 1 2 Item 1. 2. 3.
CDVSC7 & CDV7 Series Gas Fireplace VENTING COMPONENTS VERTICAL VENTING Description Vertical Vent Termination Kits Model Number Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm Collar and Ceiling Support Kit 7TDVSKVA* Vertical Vent Termination w/ 6/12 - 12/12 Flashing, Storm Collar and Ceiling Support Ki
CDVSC7 & CDV7 Series Gas Fireplace VENTING COMPONENTS HORIZONTAL VENTING Horizontal Vent Termination Kits Description Model Number Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90° Elbow, Firestop, and Cool Touch Termination w/ Siding Shield Rear Vent Cool Touch Termination w/ Siding Sh
CDVSC7 & CDV7 Series Gas Fireplace 1 VENTING COMPONENTS 7 4 8 9 HO T 5 3 2 6 11 10 VENT COMPONENTS FOR 4" X 6B\," (Simpson Duravent, Selkirk) 4" x 6Z\x" (Metal-Fab) Current Old Simpson Simpson Duravent Duravent Qty./ or MHSC or MHSC Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
CDVSC7 & CDV7 Series Gas Fireplace 69D3011 65
CDVSC7 & CDV7Residents Series Gas Fireplace Massachusetts Only — Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter 2. Approved Carbon Monoxide Detectors. Each carbon when installed within the Commonwealth of Massachusetts.
CDVSC7 & CDV7 Series Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
Based on CSA P.4.1-09 Efficiency Ratings Efficiency Ratings Model EnerGuide Ratings Model EnerGuide Ratings Fireplace Efficiency (%) Fireplace Efficiency (%) CDVR33NV7 62.6 CDVT33NV7 45.9 CDVR33NV117 57.6 CDVT33NE7 47.6 CDVR33NE7 66.8 CDVT33NSC7 47.6 CDVR33NSC117 57.6 CDVT36NV7 47.7 CDVR36NV7 47.7 CDVT36NE7 49.7 CDVR36NE7 49.7 Recherchez dans laCDVT36NSC7 47.6 brochure CDVR36NSC7 49.7 les caractéristique deCDVT42NV7 56.3 rendement CDVR42NV7 66.8 CDVT42NE7 59.