Iota V2.03 - Specifications

By default, the PPM signal is positive signal. Like this:
If your remote need negative signal, shortcut the Z servo pin (Yellow Square on the image) to
ground pin (one of the black square pins on the image) and the signal will be reversed like this:
PPM stroke calibration
o You can determine the stroke of the servo of the three axis like this:
Be sure that your remote is in trainee mode.
Press the Center button while turning on the module.
Keep the Center button pressed for about 2 seconds.
The X axis servo will shake for about one second.
Release the Center button.
The servo will move by little steps in one direction.
Press the Center button for about 0,5 second to set the limit.
The servo will shake for about one second at center.
The servo will move by little steps in opposite direction.
Again, press the Center button for about 0,5 second to set this other
limit.
The led will flash 5 times to confirm the calibration.
NOTE: The 0 180 degrees move of each axis of the module will be
constrained between these two limits. You can turn off the module
without lost these settings.
NOTE: The module will track 0 180 degrees of travel. However your
remote and/or servos can limit this below this range.
Powering the Iota (PPM)
o Use the two pins Power header to apply voltage to the module. It can be 3.7
volts to 6 volts. Note: The 5 volts from USB port is good enough to power the
module.