Finish the wall with material of your choice.
If a combustible material is
used below a at mantel shelf, consult your local build-
ing codes for minimum clearance from top of replace
opening to bottom of mantel shelf.
All joints (top, bottom and sides) where wall or deco-
rative facing material meets replace surround must
be completely sealed with a noncombustible material.
(Figs. 21 and 25)
No side wall protection is required for replaces
installed at 45° to two (2) side walls (corner installation).
FP531
Fireplace surround detail
1/29/99 djt
Must be sealed with
noncombustible material
Mantel Shelf
Finished Wall
2 x 4 Stud
Standoff
Cast Front
See mantel drawing for
shelf-to-grille dimension
1” (25mm)
Fireplace
Front (Steel)
2 x 4 Stud
FP1200
Finishing materials placement.
Brick Ledge
Noncombustible Finish Mate-
rial Only in this Area
The height that a combustible mantel is tted above the
replace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
tted) and the replace.
For the correct mounting heights and widths, refer to
Figures 22 and 23. When using paint or lacquer to nish
the mantel, such paint or lacquer must be heat resistant
to prevent discoloration.
FP1398
Combustible mantel minimum opening.
FP1398
wood mantels
8/18/03 djt
6"
(159mm)
Min.
12"
(305mm)
Min.
156O"
(38mm)
12"
(305mm)
Max.
Combustiible
Mantel and
Trim
Finished Wall
Header
Standoff
Noncombustible
Material
Brick Ledge
GrilleOpening
Fireplace Front
MA81
Combustible mantel clearances.
MA81
rev. 8/5/97
*
156O"
Ref.
**
Combustible materials
are permitted within a
shaded area shown in
Figure 26 titled
Minimum Wall
Clearances
Adjacent combustible side walls that are within mini-
mum dimensions shown in Figure 25 of the replace
opening must be protected with MHSC Wall Shield
Model SP40 or a specically built wall shield described
in Figure 20.
The special wall shield design described in Figure 20 is
an alternate method of adding protection to side walls
and can be used in place of the SP40 with the same
wall clearances specied for the SP40. Rt must =1.85
minimum.