1.2.2 Direct sending of E-mail
When a UPS event occurs, the Network Management Card can directly notify up to 4 intranet or extranet addresses by e-mail. (see E-mail
Notification and
E-mail message settings)
1.2.3 Sending text messages (SMS)
The card offers the possibility of redirecting UPS alarms to an e-mail server. The format of these e-mails is compatible with mobile telephone
e-mail/SMS transfer systems proposed by ISPs. The format to be used depends on the service provider. For example,
sms.0660256585@votre-login.activmail.net (text messages).
1.2.4 Compatibility with the Network Managment Systems (NMS) – Trap sending
The Network Management Cards are compatible with the major Network Management Systems (IBM Tivoli, CA Unicenter, HP Insight
Manager). The Management-Pac 2 offering includes the necessary SNMP plug-ins to allow an easy integration in the NMS. Events are
notified by SNMP trap.
Z NMS can subscribe on page Notified Applications
Z The trap list is given in the appendix.
1.2.5 Environment Sensor (option)
The Environment Sensor (66846) solution comprises a box to be connected to the Card Settings port of the Network Management
Cards.
Environment Sensor enables measurement of temperature and humidity around the UPS, consideration of external alarms via 2 dry
contacts and notification of alarms according to pre-programmed thresholds. (see Environmen Status and Environment Configuration
)
1.3 Technical data
1.3.1 Hardware characteristics
Dimensions
Z Dimensions (L x l x H) 132 x 66 x 42 mm
Z Weight (gr) 70 g.
Storage
Z Storage temperature -10°C to 70°C
Ambient conditions
Z Operating temperature 0°C to 40°C
Z Ambient humidity 90% RH max without condensation
Z RoHS 100% compatible
1.3.2 EMC Compatibility
When correctly installed and used in accordance with the manufacturer's instructions, the Network Management Card complies with the
following standards:
Z Safety for ATI: IEC/EN 60950-1 2002
Z EMC: EN 61000-6-2 (2002), EN 61000-6-3 (2002). IEC/EN 62040-2 (2002)
As per European directives: