PulsarTM EX7 / EX10 / EX15 EXB10 / EXB15 Manuel d'utilisation User Manual Manual de instrucciones … … … … … … ! – + % – + % MGE UPS SYSTEMS Pulsar EX : 51032233XT/AC
Thank you for purchasing the EX Uninterruptible Power Supply. The EX has been designed to provide many years of trouble-free operation. Please review the manual which has been prepared to provide you with all the necessary information concerning the installation and use of your EX. For service call 1-800-523-0142. Nous vous remercions pour l’achat de l'Alimentation sans interruption EX.
note c this equipment has been tested and found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
MGE UPS SYSTEMS, Inc.
ENGLISH IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Models EX7/EX10/EX15/EXB10/EXB15 that should be followed during installation and maintenance of the UPS batteries. c This equipment can be operated by any individual, with no previous training; c CAUTION: Risk of electric shock, even with unit disconnected from AC power source. Hazardous voltage still may be present through operation from battery.
ENGLISH introduction In critical situations, count on MGE UPS SYSTEMS Pulsar EX7, EX10 and EX15 uninterruptible power supplies (UPS). Their protection keeps your data intact and accessible. Pulsar EX7, EX10 and EX15 UPSs ensure top quality power around the clock, and continue operations during power failures. An intelligent microprocessor detects any operating anomalies of the UPS and triggers an alarm if corrective action is necessary.
options c rack installation kit: this kit is used to install Pulsar EX7, EX10 and EX15 in a 19inch rack. The kit is designed to receive two Pulsar EX7, EX10 and EX15, or one Pulsar EX10/EX15 and a battery extension unit, thus offering up to 3000 VA of power; c UM Sensor environment measurement unit: compatible with SNMP and UPS Manager 2 Unix and OS/2, or Solution PacTM, this unit measures the temperature and the relative humidity in the room where the Pulsar is installed.
software supplied with Pulsar EX7, EX10 and EX15 To meet the different operating environments of your UPS, Pulsar EX includes 2 MGE UPS SYSTEMS software programs: c EX-Driver software for Windows (on 3.5" diskettes); c Solution-PacTM network software (on CDROM).
general contents / sommaire général / sumario general Pulsar presentation ............................................................................................................................. 3 présentation de Pulsar presentación de Pulsar Pulsar EX7/EX10/EX15/EXB10/EXB15 presentation présentation de Pulsar EX7/EX10/EX15/EXB10/EXB15 presentación de Pulsar EX7/EX10/EX15/EXB10/EXB15 english .............................................................................................................
Pulsar EX7/EX10/EX15 front view / vue avant / vista delantera Pulsar EX7/EX10 rear view / vue arrière / vista trasera Pulsar EX15 rear view / vue arrière / vista trasera Pulsar EXB10/EXB15 rear view / vue arrière / vista trasera 19 11 11 wiring Site ult fa wiring Site ult fa 12 KER REA dc DC B 65V 30A 6 lk U-Ta 5V A 12 lk T 20 U-Ta MGE UPS SYSTEMS 4 8 8 PLACE STAMP HERE 1a 6a 6b 20 21 I … … … … … … ATTN: CUSTOMER SUPPORT SERVICES 1660 SCENIC AVENUE COSTA MESA, CA 92626 O 14 1b
contents getting started .................................................................................................................. 12 location ...................................................................................................................................... 12 preliminary checks .................................................................................................................... 12 connections .....................................................................
getting started location c observe the safety rules indicated at the beginning of this document. c connect the computer loads to output sockets 7 . UT O Vac 7 preliminary checks es r ? s es c check that the "on/off" button " " on the front is not pushed in; c check that rating shown on the rating label corresponds to the input voltage specification and power requirement of the load. 0V connections I max c use the AC input cord to supply input power to Pulsar as shown.
communication c the U-Talk communication port, at the rear of the Pulsar, delivers information in the form of an RS232 series link supported by the communication protocol exclusive to MGE UPS SYSTEMS. The Solution-PacTM programs use the data made available by this protocol.
operation starting up with utility power present press button "on/off" : indicator lights test device and battery test normal operation automatic sequence: 0s 5s 1a to 1f on 7s 1a to 1f flashing 17 s 1a to 1d indicating the 1a to 1d indicating the recharge percentage of the battery (here 50%) remaining battery time percentage (here 50%) several beeps 1 s beep output off 14 output off 1e on 1e off 1f on 1f on silence your load is supported by the battery Pulsar EX: E-51032233XT/AC sile
starting up with out utility power press "on/off" button: indicator lights test device and battery test normal operation on battery automatic sequence: 0s 5s 1a to 1f on 7s 1a to 1f flashing 17 s 1a to 1d indicating the 1a to 1d indicating the remaining autonomy percentage (here 50%) remaining battery time percentage (here 50%) several beeps 1 s beep output off MGE UPS SYSTEMS output off 1e on 1e flashing 1f on 1f on 3 s beep your load is supported by the battery Pulsar EX: E-51032233
operation on battery no utility power break in utility power warning alarm at low battery 0 mn Pulsar switches off automatically x + ε mn x mn 1a to 1d indicating the if Pulsar is operating on battery without load: UPS switches off 1a to 1c off 5 mn 1a to 1f 1a to 1f off off remaining battery time: here, between 75 and 87% 1d flashing 1e flashing 1e flashing 1f on 1f on 1 beep every 3 s 1 beep every 10 s your load is supported by the battery you have less than 12% battery time remaining: p
overload operating anomalies utility power present device fault 1a flashing 1b flashing 1d flashing 1e off 1f on 1 beep every second automatic load transfer to bypass no utility power present 1d flashing battery fault A battery test is carried out while Pulsar, is in start-up mode, then automatically every 7 days (interval times adjustable using EX Driver).
www.kesintisizservis.