Stove Placement Requirements
Nova must be placed in a room with a source of fresh air.
Stove must be placed so that no combustibles are within, or can swing
within 36" (914mm) of the front of the stove (drapes, doors, etc.).
Floor protection must extend around the front, sides, and rear of the
stove, according to listed clearance requirements below. Floor
protection must be made of a non-combustible material and at least
0.018” (0.45 mm) thick with the minimum R-values shown in the
installation specifications below.