Owner Manual
Table Of Contents
- Table of Contents
- Safety Precautions
- Features and Specifications
- Stove Installation
- Planning the Installation
- Stove Placement Requirements
- Standard Installation: Through back wall
- Standard Installation: 90-degree elbow
- Chimney Requirements
- Chimney Connector Requirements
- Chimney Termination Requirements
- Special Installation: Exterior Factory-Built Chimney
- Special Installation: Masonry Chimney
- Special Installation: Masonry Fireplace
- Installing the Brick and Ceramic Fiberboard
- Catalytic Combustor
- Ash Retainer
- Stove Top Thermometer
- Initial Curing
- How Nova Works
- Regular Maintenance and Troubleshooting
- Monthly Maintenance
- Annual Maintenance
- Catalytic Combustor Replacement
- Lifetime Limited Warranty
9 | Page Nova Owner’s Manual | © MF Fire 2017
Standard Installation: Through back wall
Minimum Clearance Requirements
A Side wall to unit
20” (508 mm)
B Back wall to unit
18.5” (305 mm)
G Floor protection, side and back
8” (200 mm)
H Floor protection, front
16” (407 mm)
I Floor protection, chimney connector
2” (51 mm)
Floor protection must be made of a non-combustible material and at
least 0.018” (0.45 mm) thick with a minimum R-value of 0.9
ft2•hr•°F/Btu/in of minimum dimensions 54” x 38.5”. NOTE: This is a
different R-value than the through 90-degree elbow installation.