Product Manual

Installation and Operational Manual
00122-993-01 June 8, 2010
7
CONTROL HYDRAULICS INSTALLATION (Continued)
system.
2. Standard pump, valve, tank and hose kits make up the complete system.
3. This diagram may be used to install an entire system, or part of a system, depending
upon kits supplied, and existing components on truck.
4. Alternate proven methods and components are acceptable to suit various truck model
requirements.
5. Hydraulic components should be kept as clean as possible during assembly
operations.
6. Galvanized pipe and pipe fittings should not be used because flaking of galvanizing
material can cause damage to major hydraulic components.
7. A pipe joint sealant, compatible with hydraulic oil, must be applied to all screwed
fittings. (Teflon tape is not recommeneded.)
8. Sufficient hose should be allowed for raising dump body without kinking or stretching
hose.
9. Hose should be protected where severe wear may be caused by vibration or sliding
movement.
10. Long runs of hose should be supported by nylon ties or clamping.
11. Auger and Spinner pressure and return hoses may be reversed for proper motor
rotation.
12. Three hose lines to rear of truck may be installed inside truck frame, under dump body
floor, and secured in place.
13. Use hose manufacturers recommendations for fitting reusable hose ends.
1. This diagram is
Meyer Products complete recommended hydraulic