Datasheet

1490413 datenblatt.doc
Page 2 of 3
Vibration
Resistance
N/A
V<0.02V
Charge at 0.1C for 14 hrs,
then leave for 24 hrs. Check
battery before / after vibration
Amplitude: 1.5mm,
Vibration: 3000CPM (and
direction for 60 mins)
Unit cell
Impact Resistance N/A
V<0.02V
Charge at 0.1C for 14 hrs,
then leave for 24 hrs. Check
battery before / after drop the
wooden board of thickness:
30 mm
Height: 50 cm, test for 3
times. Direction is not
specified
Unit cell
4. Configurations, Dimensions And Markings
Please refer to the related drawing.
5. External Appearance
The cell / battery shall be free from cracks, scars, breakage, rust, discoloration, leakage and
deformation.
6. Warranty
One year limited warranty against workmanship and material defect.
7. Cautions
1. Reverse charging is not acceptable.
2. Charge before use.
3. Do not charge / discharge with more than the specified current.
4. Do not short circuit the cell / battery.
5. Do not incinerate or mutilate the cell / battery.
6. Do not solder directly to the cell / battery.
7. The life expectancy may be reduced if the cell / battery is subjected to adverse conditions,
like extreme temperature, deep cycling, excessive overcharge /over-discharge.
8. Store the cell / battery in a cool dry place.
9. Keep away form children. If swallowed, contact a physician at once.