User`s guide

Operation
By-Weight PLU
Service Mode
Call the PLU. If PREPACK is displayed on the EDIT screen, press that key to toggle to SERVICE. Place
the item on the platter and press PRINT to issue a label. When the item is removed from the platter,
the PLU will automatically clear.
Prepack Mode
Call the PLU. If SERVICE is displayed on the EDIT screen, press that key to toggle to PREPACK. Place
the item on the platter. A label will automatically issue. Take the label and remove the item from the
platter. The PLU will remain on the screen to weigh additional items. Press CLEAR when you are
finished weighing.
The By-Weight PLU Edit Screen is shown below. By-Weight PLUs can be priced in three ways:
Priced "Per Pound" - Typically weighed items are priced per the pound. The weight
multiplied by the unit price equals the total price of the product to the customer.
Priced "Per Fraction of a Pound" (fractional) - The item may also be priced by the fraction
of the pound (where legal and desired). Pricing per 1/4 pound and per 1/2 pound is
available.*
*Note: most
locations, Price Per
Pound/KG is the only
acceptable method of
pricing. In this case,
the pricing is set when
the scale is calibrated
and sealed by a
Weights and
Measures certified
technician.
"Pounds for" price - The PLU may be sold with a pounds-for price (rather than price per
pound). (e.g. 2 pounds for $1.00).*
Notes:
Depending on the setting of the function “Print after Motion” and “Print Key Always Active” your
scale may function differently than described above. If the set up function “Print After Motion” is
set to NO, you will need to press the PRINT button to print a label for each item. When this is set
to YES (the factory default setting), the label prints automatically after you place the item on the
platter.
If the function “Print Key Always Active” is set to YES, the PRINT key will issue a label when
pressed. If set to NO, the PRINT key will on print one label per item.
UC-ST User’s Guide