PS Shipping Scales PS60G PS60U PS6L PS30 PS3L Technical/Operator Manual For PS units with GEOCAL™ E15402600A 08/04
©Mettler-Toledo, Inc. 2004 No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose without the express written permission of Mettler-Toledo, Inc. U.S. Government Restricted Rights: This documentation is furnished with Restricted Rights.
METTLER TOLEDO® Customer Feedback Attention: Retail Quality Manager - MTWR If you have a problem with one of our products or publications, or just a suggestion on how we can serve you better, please fill out this form and send it to the address on the opposite side of this page (U.S. postage paid), or fax it to us at (614) 438-4355. Your feedback will help us to improve product performance, quality, and service.
FOLD THIS FLAP FIRST NO POSTAGE NECESSARY IF MAILED IN THE UNITED BUSINESS REPLY MAIL POSTAGE WILL BE PAID BY ADDRESSEE Mettler-Toledo, Inc. Retail Quality Manager - MTWR P.O. Box 1705 Columbus, OH 43216 USA Please seal with tape.
INTRODUCTION This publication is provided as a guide for individuals in the operation, use, and care of this METTLER TOLEDO product. Further information or assistance regarding this product may be obtained by writing to: METTLER TOLEDO 1900 Polaris Parkway Columbus, OH 43240-2020 (614) 438-4400 WARNING! This equipment generates, uses, an can radiate radio frequency energy and if not installed and used properly, i.e.
PRECAUTIONS READ this manual BEFORE operating or servicing this equipment. FOLLOW these instructions carefully. SAVE this manual for future reference. DO NOT allow untrained personnel to operate, clean, inspect, maintain, service, or tamper with this equipment. WARNING DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, SERVICING, CLEANING, OR REMOVING THE FUSE. FAILURE TO DO SO COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE.
CONTENTS 1 Introduction...........................................................................................................1-1 Standard Features ......................................................................................................................1-2 Optional Accessories ..................................................................................................................1-2 Specifications....................................................................................
4 Operating Instructions ........................................................................................ 4-1 Keypad and Display ...................................................................................................................4-1 Operator Functions ....................................................................................................................4-1 Parcel Weighing.....................................................................................................
Chapter 1: Introduction Standard Features 1 Introduction Thank you for purchasing a PS shipping scale from METTLER TOLEDO. The legal-for-trade model of the PS60 shipping scale is a low-profile, 150 × 0.05 lb (60 × 0.02 kg) capacity scale designed to meet the needs of the legalfor- trade parcel/manifest markets. The PS60 also features an auto-ranging capacity of 0 - 60 lb × .02 lb / 60 - 150 lb × .05 lb, as well as a weight classifying model with the same capacity as the auto-ranging model.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Standard Features The following are standard features built into each PS shipping scale.
Chapter 1: Introduction Specifications Specifications The PS shipping scale conforms to and operates best within the specifications described in this section. Physical Dimensions • • • • • • • • Base dimensions: 290 mm × 335 mm (11.42 in. × 13.19 in.) Platter dimensions: 300 mm × 350 mm (11.81 in. × 13.78 in.) Max. dimensions w/indicator: 358 mm × 350 mm (14.09 in. × 13.78 in.) Height with platter: 80 mm (3.15 in.) Height with platter and battery: 90 mm (3.54 in.) Weight with display: 6.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual • • • • • • • • Base dimensions: 290 mm × 335 mm (11.42 in. × 13.19 in.) Platter dimensions: 300 mm × 350mm (11.81 in. × 13.78 in.) Maximum dimensions w/indicator: 358mm x 350mm (14.09in. x 13.71.in.) Height with platter: 80 mm (3.15 in.) Height with platter and battery: 90 mm (3.54 in.) Weight (w/display, non-battery): 6.65 kg Weight (w/display, w/battery): 7.
Chapter 1: Introduction Standards Compliance Environmental Requirements The PS60 operating range is −10° to +40°C (+14°F to +104°F) at 10 to 90% relative humidity, non-condensing. The PS30 and PS3L operating range is 0° to 40°C (+32° F to +104°F) at 10 to 90% relative humidity, non-condensing. The PS6L operation range is +10° to +40°C at 10 to 90% relative humidity, non-condensing. The shipping and storage temperature range is −20° to +60°C (-4°F to +140°F) at 0 to 95% relative humidity, non-condensing.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual RFI Susceptibility The PS60 meets the requirements of the European Norm. 45501 for RFI susceptibility as listed below with a maximum of one display increment of change when calibrated for recommended builds.
Chapter 1: Introduction Electrical Interfaces Figure 1-d: PS6LH Electronic Interface Diagram Figure 1-e: PS60U/PS30 Electronic Interface Diagram 1-7 (08/04)
FOR YOUR NOTES
Chapter 2: Installation and Calibration Unpacking and Setup . 2 Installation and Calibration This chapter gives detailed instructions and important information you will need to install the PS successfully. Please read this chapter thoroughly before you begin installation. This information is also covered in the PS Operator Instructions. Unpacking and Setup Please inspect the package as the carrier delivers it.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual 4. Level the scale by turning the adjustable feet on the bottom of the unit. When the bubble in the bubble indicator is within the circle, the PS is level (see Figures 2-a, 2-b,). The feet must be adjusted so the scale does not rock. M E T T L E R U TN I O LT S VV E D O O N / O F F O - Leveling Feet (4) Figure 2-a: PS,Leveling Feet Incorrect Bubble is not within circle Correct Bubble is within circle Figure 2-b: Level Indicator 5.
Chapter 2: Installation and Calibration Initial Calibration using GeoCal NOTE: Inside of barrel is positive.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Basic Information The following sections describe some basic information that you will need to know as you install, calibrate, and use the PS in normal operating mode. The Display The PS’s display consists of six digits and five cursor positions. Each digit is composed of seven segments and is 12 mm high.
Chapter 2: Installation and Calibration Initial Calibration using GeoCal The functions for each key in normal operating mode are as follows: • UNITS—Press UNITS to switch between the selected main units and alternate units. • ZERO—Press ZERO to zero an empty scale. The reading must be within 2% of the calibrated zero. If the scale is in Sleep mode (as defined in the Sleep program block), press ZERO to “awaken” the scale.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Initial Calibration using GEOCAL™ The PS shipping scale must be calibrated when the unit is initially installed to correct for local gravity variations thereby ensuring accurate weighing results. If the GEOCAL™ capabilities of your PS unit have been activated, the unit has been pre-calibrated from the factory.
Chapter 2: Installation and Calibration Initial Calibration using GeoCal (08/04) 2-7
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual The sequence for selecting your GEOCAL™ code is as follows: 1. Press the ZERO key to display the first code option and continue pressing it to scroll through all of the available codes. 2. Press the UNITS key to select the code for your location. The display will then prompt done. Press the UNITS key again to restart the scale.
Chapter 2: Installation and Calibration Full Calibration CAL Jumper W1 Figure 2-g: CAL Jumper on Main PSXXG PCB Figure 2-h: CAL Jumper on Main PSXXU PCB (08/04) 2-9
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual 4. Connect the power to the scale. This prompt only appears if the calibration jumper is removed. 5. Enter the setup mode by pressing and holding the UNITS key for up to eight seconds until the message Setup is displayed. Release the UNITS key. 6. Press the UNITS key several times until the Cal prompt appears, then press ZERO to display YES or NO. Select Yes to calibrate or select No to abort calibration.
Chapter 2: Installation and Calibration Full Calibration Display Prompt 30-02 70-05 30-01 30-ni 70-ni 70-no Build 30 x 0.02 kg 70 x 0.05 lb 30 x 0.01 kg 0-15 / 15-30 kg Multi-Interval 0-7 / 7-70 lb Multi-Interval 0-7 / 7-70lb/oz. Multi-Interval 11. Press UNITS to select the displayed capacity/increment option. 12. Press UNITS until the CAL prompt appears, then press ZERO to display Y or N. Select Y(es) to calibrate or select N(o) to abort calibration.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Metrological Seal Installation If a wire seal is required for W & M requirements, the PS can be sealed after calibration and setup by installing a wire seal on the Main PCB access cover, as shown in Figure 2-i. Figure 2-i: Wire Seal Installation USB Installation USB scale connection is very automatic. When you connect the scale to your PC’s USB port, the PC will automatically sense the scale.
Chapter 2: Installation and Calibration Full Calibration A dialog box stating “New Hardware Found” will appear. Immediately, the PC will begin to “Build Driver Information Database”. 1. Once this is complete, a “Add New Hardware” Wizard will appear. Select the bottom choice of “Display a list of all the drivers in a specific location, so you can select the driver you want”. 2. If the drivers are not immediately found, insert your Windows 98 CD and locate the proper directory. 3.
FOR YOUR NOTES
Chapter 3: Configuring the Setup Parameters Configuring Setup Parameters 3 Configuring the Setup Parameters This chapter discusses basic information related to PS configuration and specific instructions on configuring each program block and operating parameter. Basic Setup Information The following sections describe some basic information that you will need to know as you configure the setup parameters for the PS.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual • Disconnect the power from the scale. Changes will not be saved. Configuring Setup Parameters This section describes the program blocks that govern normal operation including: • • • • • • • • Push Button Zero * Zero Cursor * Power-up Units * Build * Alternate Units Mode * Filter Baud • • • • • • • • ASCII Parity Stop Bits Protocol Sleep GEOCAL™* Calibration * End This is the order that they appear in the prompts.
Chapter 3: Configuring the Setup Parameters Configuring Setup Parameters Zero Cursor Program Block The Zero Cursor program block lets you enable or disable the center of zero indicator on the PS. (Metrology PCB jumper must be removed.) To configure the program block: 1. Press UNITS to display the 0 CurS prompt, then press ZERO. 2. Press ZERO to display the desired approval setting, enable or disable. 3. Press UNITS to accept the displayed option. The PS continues to the Power-up Unit program block.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual PS6L Power-up units = Pounds 149-ni 0-10 lb. x 0.1 oz, 10-70 lb. x 0.2 oz, 70-150 lb. x 0.5 oz * 150-n5 0-5 x 0.005 lb., 5-25 x 0.05, 25-150 x 0.1 lb. Multi-interval PS30/PS3L Power-up units = Pounds 70-05 70 x 0.05 lb. 70-ni 0-7 / 7-70 lb Multi-Interval 70-no 0-7 / 7-70 lb/oz. Multi-Interval. Power-up units = Metric 30-01 30 x 0.01 kg 30-02 30 x 0.02 kg 30-ni 0-15 / 15-30 kg Multi-Interval * Default for that model.
Chapter 3: Configuring the Setup Parameters Configuring Setup Parameters Filter Program Block The Filter program block lets you configure the noise filter that is used in determining weight stability on the scale. The PS disregards environmental noise such as vibrations that affect the weighing accuracy according to the filter setting. To configure the program block: 1. Press UNITS to display the FiLtEr prompt, then press ZERO. 2. Press ZERO to display the desired noise filter.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Parity Program Block The Parity program block lets you select the parity option for data transmission. Parity is an error checking mechanism. To configure the program block: 1. Press UNITS to display the PAr prompt, then press ZERO. 2. Press ZERO to display the desired parity option. Options include: • Space • Mark • Odd • Even • None 3. Press UNITS to accept the parity option. The PS continues to the Stop program block.
Chapter 3: Configuring the Setup Parameters Configuring Setup Parameters Sleep Program Block The Sleep program block lets you configure the sleep timer. Power consumption is reduced by approximately 60% while in Sleep mode. IMPORTANT: For battery powered units, it is important to turn battery power off (using the rocker switch underneath the scale) when the scale is not in use. To configure the Sleep program block: In normal operating mode the scale is powered-up by pressing the ZERO (ON/OFF) key. 1.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual • • • • Default—Reset all program block parameters to standard MT values, then exit setup mode. Abort—Exit setup mode but do not save any changes made in this session. Save—Do not exit setup mode at this time. PS returns to the first program block. Def x—Company specific.
Chapter 3: Configuring the Setup Parameters Configuring Setup Parameters This page was intentionally left blank.
FOR YOUR NOTES
Chapter 4: Operating Instructions Keypad and Display 4 Operating Instructions This chapter gives information that an operator will need to become familiar with the scale and perform its functions in normal operating mode. The scale operates based on the current program block configuration. Please refer to Chapter 3 for more information on configuring the PS. Keypad and Display The PS has a simple LCD weight display with two keys that are used to perform scale functions.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual You may wish to recapture zero periodically when the scale is in continuous use. It is not necessary to press ZERO before each transaction. 1. Press ZERO to capture zero. The display reads 0.00 and a cursor appears above the zero indicator in the legend. 2. Place the parcel to be weighed on the platter. The display reads the parcel weight with a cursor above the current weight units legend. 3.
Chapter 5: Service and Maintenance Cleaning and Regular Maintenance 5 Service and Maintenance This chapter gives information on servicing, upgrading, and maintaining the PS including cleaning and regular maintenance, troubleshooting, and installing optional equipment kits. Cleaning and Regular Maintenance You may need to wipe the keypad and platter with a clean, soft cloth that has been dampened with a mild cleaner. Do not use any type of industrial solvent such as toluene or isopropanol (IPA).
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Error Code Section Error codes are displayed on the weight indicator with a leading “E” to distinguish themselves from weight data. Code Meaning E1 ROM (checksum) error E2 RAM error Action Replace the circuit board to clear this error (call Mettler Toledo Service) Replace the circuit board to clear this error (call Mettler Toledo Service) Setup and /or calibration information has been lost.
Chapter 5: Service and Maintenance Troubleshooting Main PCB (PS60G only) From PC - DB25-F RS232 To PS - DB9-M SERIAL PORT (Male) 2 TRANSMIT 3 RECEIVE 3 RECEIVE 2 TRANSMIT 7 SIG 1 or 5 SIG GROUND GROUND Table 1 Standard PC RS232 DB-25 To PS From PC - DB9-F RS232 To PS – DB9-M SERIAL PORT (Male) 2 RECEIVE 2 TRANSMIT 3 TRANSMIT 3 RECEIVE 5 SIG 1 or 5 SIG GROUND GROUND Table 2 Standard PC RS232 DB9 To PS To test the Main PCB: (Unit must be setup for standard MT communications (Default)): 1.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Indicator Locked To test operation of the indicator, remove power, then reapply. With power to the unit, add weight. If no motion is displayed, replace either the load cell or the Logic PCB.
Chapter 5: Service and Maintenance Installing the Battery Kit WARNING! Always remove all power before operating on any equipment. Mettler-Toledo recommends that only qualified technicians open the unit up for maintenance and repair. If you must open the PS, read this section carefully to avoid damage to the internal components. 1. Remove the power and turn the PS over on the on the platter side. Be extremely careful not to damage the display. 2. Install the plastic D-cell battery holder P/N 13257500A.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual 4. Insert the on/off rocker switch (P/N 14262400A) into the switch hole of the battery cover (P/N 14545200A) noting the orientation of the switch. Six alkaline 1.5 VDC, D-size batteries (P/N 13293700A) are required for operation. 5. Insert the two fasteners (P/N 12051300A) into the battery cover. 6. Install the terminal spade lugs on the terminals of the switch that is installed into the battery cover. 7.
Chapter 5: Service and Maintenance Installing the Battery Kit 8. Carefully attach the battery cover paying close attention to the routing of the cable to the Main PCB. Close the battery cover fasteners.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Installing the Base Mount Display A base mount display unit (0270, 2-key indicator) can be installed if one was not ordered initially for the PS shipping scale (PS60 and PS6L models only). To install the base mount display: 1. Attach the display unit to the bottom of the PS with the two M4 10mm screws (P/N R0550100A) as shown below: 2. Install the display interface harness from the display as shown.
Chapter 5: Service and Maintenance Installing the Ball Top Transfer Platter Installing the Ball Top Transfer Platter A ball top transfer platter is available for the PS. To install the ball transfer platter: 1. Remove the platter supplied with the PS. 2. Place the ball top transfer platter on the PS. 3. Ensure that the ball top transfer platter drops into place without mechanical interference. Note: If the unit fails to capture zero after power-up, re-calibration will be required.
FOR YOUR NOTES
Chapter 6: Parts and Accessories PS60/PS6L/PS60U 6 Parts and Accessories Please refer to the following diagrams and parts lists when ordering parts and accessories for the PS shipping scale.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual PS60/PS6L/PS60U Scale Parts Figure 6-a 6-2 (08/04)
Chapter 6: Parts and Accessories PS6 Parts List PS6 Parts List (*) Some part numbers may have a revision letter in front of them. (**) Indicates not shown if Figure 6-a.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual PS30/PS3L Scale Parts Figure 6-b 6-4 (08/04)
Chapter 6: Parts and Accessories PS3 Parts List PS3 Parts List (*) Some part numbers may have a revision letter in front of them. (**) Indicates not shown in Figure 6-b.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Weight Display Parts Parts List—Weight Display Ref # Part Number Description 1A *15705300B Display PCB Assembly W/Cable 1 1B *15640800A Display Base 1 1C R0550100A Screw,M4X10,PH,THD,w/Washer 2 (*) Some part numbers may have a revision letter in front of them.
Appendix A: Host Interface Communication Parameters Appendix A: Host Interface The METTLER TOLEDO PS shipping scale can function as a peripheral device to a host computer. In host mode you can: • Calibrate the scale • Configure setup parameters • Request and receive weight data when the scale is in a stable state The scale does not reply to host weight commands if it is in calibration mode or if the scale cannot capture zero on power-up.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual ASCII Characters and Conversions ASCII CHAR. DEC HEX 76543210 ASCII CHAR.
Appendix A: Host Interface Scale Status Byte Format ASCII CHAR. DEC HEX 76543210 ASCII CHAR.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Toledo Protocol Host Commands Following is a listing of host commands and scale responses. Brackets “<>” are used to indicate that the characters within are a description of the transmitted data and are not part of the transmitted data string. indicates an ASCII Start Of Text character (HEX 02). indicates an ASCII Carriage Return (HEX 0D). Host Command Description W* Send normal resolution weight data. XXX.
Appendix A: Host Interface Scale Status Byte Format Scale Status Byte Format When communicating in host mode using the standard Toledo protocol, the PS may send status bytes containing information such as motion and over/undercapacity conditions. The message ? indicates transmission of a status byte. The status byte sent is an ASCII character that must be converted to binary form for decoding the bits.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual Status Byte Bit No. Bit Description 6 1 = New status data available. 0 = Host has read data. 5 Bit is always a 0. 4 1 = ROM test failed. 0 = ROM test passed. 3 1 = RAM test failed. 0 = RAM test passed. 2 Bit is always a 0. 1 1 = Calibration Required. 0 = Calibration Data OK 0 1 = EEPROM test failed 0 = EEPROM test passed. Calibrate Using Host Interface The PS shipping scale can be calibrated using the host interface.
Appendix A: Host Interface Scale Status Byte Format 6. Add the requested calibration weight to the scale, then send the command Y to continue. The scale responds CAL DONE or INCORRECT AMOUNT OF WEIGHT . Configure Scale Parameters Using Host Interface Configuration parameters can also be sent using the host interface. A command to send a new scale configuration over the host interface is available in the METTLER TOLEDO command set. To configure using the host interface: 1.
METTLER TOLEDO PS Shipping Scale Technical/Operators Manual The table below lists the programming options available in each program block as they are used in Host Interface Setup. When downloading the scale setup it is strongly recommended that you modify only the selections that you need to change in the current setup bytes sent by the scale. Leave the values of all other setup bytes as they were when sent from the scale (including the selections that are currently not used).
Appendix A: Host Interface Scale Status Byte Format You can obtain the current configuration by sending the S command. Then you can abort without changing by sending the A command to abort. Before sending the DONE reply, the configuration file is analyzed just as if it had been constructed using the keyboard. 3. Send the command desired new set of bytes to the scale: Y1Y2 ... Y19Y20 4. The scale will check to make sure the requested bytes are valid, then will echo the request: Y1Y2 ...
FOR YOUR NOTES
Appendix B: USB Host Interface The USB 1.1 full speed (12Mbs) interface on this scale is used in applications where a USB interface, which conforms to the Microsoft™ USB POS HID, is required. References The following documents can be found on the official USB Web page. http:/www.usb.org/developers/docs.html Universal Serial Bus Specifications, Revision 2.0 http:/www.usb.org/developers/hidpage.html Universal Serial Bus Device Class Definition for Human Interface Devices (HID), Version 1.
Protocol This interface supports the standard Universal Serial Bus HID Point of Sale Usage Tables for scales. Refer to the Universal Serial Bus HID Point of Sale Usages Tables document for details on this protocol.
FOR YOUR NOTES
METTLER TOLEDO 1900 Polaris Parkway Columbus, Ohio 43240-2020 P/N: E15402600A (08/04) METTLER TOLEDO®is a Trademark of Mettler-Toledo, Inc. © 2004 Mettler-Toledo, Inc. Printed in U.S.A.