Specifications

2•5
Rev
. 10/04
Auxiliary Floor Receiver
DESCRIPTION
The Auxiliary Floor Loop receiver connects to a compatible
Ultra•Max controller (Ultra•Controller – 4 Channel,
Ultra•Controller – 2 Channel, 8 Amp and ADS Digital 216) to
provide an increased floor-level detection field. The Auxiliary
Floor Loop receiver can be used in exits with pedestals spaced
up to maximum of 9’ (2.74m) apart and a minimum of 5’ (1.5m).
Two loops can also be used in a dual configuration when one
controller is powering two exits or one exit is utilizing a split
(three pedestals) configuration.
FEATURES/BENEFITS
• Improved system performance with certain tag orientations up
to 4’ (1.22m) high.
• Enhances the lower detection zone which is critical for
retailers that tag or source tag shoes, which could be worn on
the feet of potential shoplifters.
• Effective in increasing the detection of any tagged item that
might be stuffed into the bottom of a shopping bag that is
held close to the floor.
• Compatible with Digital ProMax, Digital Euro ProMax,
DoorMax and UltraPost pedestals.
SPECIFICATIONS
Dimensions
Receiver Box
Height: 9.2cm (3 5/8in)
Width: 12.0cm (4 3/4in)
Depth: 5.3cm (2in)
Interconnect cable
Length: 12m (40ft)
Receiver loop
Length: 15m (50ft)
Floor Cut
Dimensions: .75” (1.9cm) deep below the level of the concrete
and .25” (0.64cm) wide
Environmental
Operating Temperature:
0° to 50°C (32° to 122°F)
Relative Humidity:
0 to 90% non-condensing
Regulatory Compliance
MC 47 CFR, Part 15
EN 300 330
EN 301 489
RSS 210
Safety
UL 60950
CSA C22.2 No 60950
EN 60950
Product Code
ZSLOOP-AUX