Specifications

1•15
Rev. 10/04
Ultra•Exit Concealed 5
Meter System
DESCRIPTION
The Ultra•Exit Concealed 5 Meter System is an aesthetic
anti-shoplifting solution for high fashion and specialty store
formats; however any visually conscious retailer with a 3.7m
(12’) – 5.4m (18’) wide storefront can utilize this solution.
The Ultra•Exit Concealed 5 Meter System consists of
three key antennae elements:
Overhead: These new state of the art transceivers that
have an oval shape approximately 1.8m (7’) long. Two
transceivers will be mounted horizontally overhead from
2.4m (8’) – 3m (10’) from the floor. The antennas are
packaged in a decorative, low pr
ofile housing. They can
be suspended or surface mounted.
Perimeter Antenna – A loop will surround all four
sides of the pr
otected entrance. The standard
installation of the loop will be concealed in the columns.
It also can be surface mounted (with optional trim kits).
A saw cut in the floor is required to be installed.
Floor Antenna – The floor loops will only function as a
r
eceiver antenna. These loops will require a saw cut in
the floor to be installed.
COVERAGE
FEATURES/BENEFITS
Eliminates the pedestal objections from retailers’ key
pur
chase criteria.
Address the transition needs associated with the
discontinuation of microwave systems.
Traditional pedestal systems cannot be installed in some
storefronts and discrete anti-shoplifting detection systems are
preferred by a growing number of mall management companies.
SPECIFICATIONS
Power Supply (non-European)
Primary Input: 100-120Vac or 220-240
Vac @ 50-60Hz
Primary Power Fuse: 5A, 250V
Current Draw: 3.3A @ 120; 2.7A @ 240
Input Power: <300W
Transmitter
Outputs: 3 ports
Operating Frequency: 58 kHz (±200Hz)
Transmit Burst Duration: 1.6ms
Transmit Current: 16A peak
Burst Repetition Rate: 75Hz (normal) based on 50Hz ac; 90Hz
(normal) based on 60Hz ac
Receiver
• Inputs: 5 ports
• Center Frequency: 58 kHz
Alarm
• Alarm Relay Output: DPDT contacts
• Lamp/Audio Duration: 1-30 sec.
• (1 sec. increments)
Environmental
• Ambient Temperature: 0°C to 50°C (32° F to 122° F)
• Relative Humidity: 0-90% non-condensing
Regulatory
Safety: UL1950, Can/CSA C22.2, No. 950 EMC: 47 CRF, Part
15, RS 210 Issue 3
Product Codes (U.S.) *
• ZALD-12 Ultra•Exit Concealed 12 Ft. System
• ZALD-15 Ultra•Exit Concealed 15 Ft. System
• ZALD-18 Ultra•Exit Concealed 18 Ft. System
• ZALD-12A Ultra•Exit 12 Ft. Pre-Wire Kit
• ZALD-15A Ultra•Exit 15 Ft. Pre-Wire Kit
• ZALD-18A Ultra•Exit 18 Ft. Pre-Wire Kit
• ZALD-12B Ultra•Exit 12 Ft. Final Sys Kit
• ZALD-15B Ultra•Exit 15 Ft. Final Sys Kit
• ZALD-18B Ultra•Exit 18 Ft. Final Sys Kit
• ZALD-EXTB Ultra•Exit 12' - 18' EXTRUSION/CABLE KIT BLK
• ZALD-EXTC Ultra•Exit 12' - 18' EXTRUSION/CABLE KIT CLR
• 0352-0212-01 Bracket Mount Option Kit
* Not Available in Europe
W
ill be available in February 2005
U.S. Europe
Max. ped.
Spacing
X
12m (40’)
Total exit
coverage
3.7m (12’) –
5.4m (18’)
3.7m (12’) –
5.4m (18’)
Max. ped.
Spacing
X
X
Total exit
coverage
X
X
Single