Specifications
1•9
Rev. 10/04
MegaMax
DESCRIPTION
MegaMax systems are designed for European retailers. The
pedestals have the same clear, acrylic finish as the Euro Pro-Max
pedestals. The system provides 2 m (6.56 ft.) of coverage
between pedestals, with an additional 1m (2.5 ft) or backfield
behind each pedestal.
Ranger receivers or Satellite Receiver—used in place of a
pedestal—provide system design options or help achieve an
open architectural appearance.
COVERAGE
FEA
TURES/BENEFITS
•
Upscale, attractive.
• High detection rate.
SPECIFICATIONS
Power Supply
• Primary Inputs: 100-120Vac or 220-240Vac @ 50-60Hz
• Primary Power Fuse: 3A, 250V slo-blow
• Current Draw: 2.0A peak
• Input Power: <180W
Transmitter
• Outputs: 2 ports (two antennas multiplexed)
• Operating Frequency: 58 or 60kHz
• Transmit Burst Duration: 1.6ms
• Transmit Current: 16A peak
• Repetition Rate: 75Hz (based on 50 Hz ac); 90 Hz
(based on 60 Hz ac)
• Tx Coil Resis: 4.4 ohms (±5%)
Alarm
• Alarm Relay Output: SPDT contacts
• Contact Switching Current: 0.25A max.
• Contact Switching Voltage: 28V max.
• Lamp/Audio Duration: 1-30 sec. (1 sec. Increments)
Environmental
• Ambient Temperature: 0 to 50º C (32º F-122º F)
• Relative Humidity: 0 to 90% non-condensing
Regulatory
• Emissions: FCC Part 15
• Safety: UL 1950; EN 60950 (CE); Can/CSA C22.2 No. 950-95
Electrical Specifications - Power supply
• Primary input: 100-240Vac, 50-60Hz
• Line Fuses: 5A, 250V, T127
• Current Draw: 4.5A peak
• Input Power: 400W
Mechanical
• (LxWxD) 149 x 71.4 x 14 cm (58.5 x 28 x 5.5 in.)
• Weight: 22.2 kg (48.8 lb)
Product Codes (Europe)*
•
ZAEP9030-1 MegaMax Single
• ZAEP9030-1F1 MegaMax Single with Ranger
• ZAEP9030-1S1 MegaMax Single with Satellite receiver
• ZAEP9030-1F2 MegaMax Single with Dual Ranger
• ZAEP9030-1S2 MegaMax Single with Dual Satellite receiver
• ZAEP9030-2 MegaMax Dual
• ZAEP9030-3 MegaMax Split
• ZAEP9030-4 MegaMax Quad
Product Codes With Ultra•Controller-4 Channel
(Europe)
• ZSEP4 Single Antenna
• ZAEP4-3 Split System
• ZAEP4-4 Quad System
*See Eur
o Pr
o-Max III for U.S. use
U.S. Europe
Single
Dual
Max. ped.
spacing
X
X
Total exit
coverage
X
X
Max. ped.
spacing
1 m (3.2’)
2 m (6.5’)
Total exit
coverage
2 m (6.4’)