Specifications

1•4
Rev. 10/04
Ultra*Post
®
DESCRIPTION
The Ultra*Post detection system is made up of a Primary
pedestal and, typically, a Secondary pedestal. The Primary
pedestal contains all the components necessary to
operate on its own - transmitter, receiver, audible alarm,
visual alarm and power supply. By itself, the Primary
pedestal creates a detection field of 0.9m (3 ft.) on both
sides. The Secondary pedestal operates in conjunction
with a Primary pedestal. It does not contain power, audible
alarms or visual alarms. The Primary/Secondary (dual) configuration
provides up 1.8 m (6 ft.) of coverage between pedestals.
OPTIONS
• Alarm counter
• Ultra*Post Shield to minimize backfield.
• A crash kit to safeguard pedestals from shopping cart collisions
COVERAGE
FEATURES/BENEFITS
Low profile, attractive design.
Self contained pedestal with integrated power supply for easy
installation and lower cost.
One- or two-pedestal configurations.
SPECIFICATIONS
Receiver
Inputs: 1 Port (two coils, multiplexed)
Center Frequency: 58 or 60 kHz
Transmitter
Outputs: 1 Port (two coils, multiplexed)
Operating Frequency: 58 or 60 kHz
Alarm
Alarm Relay output: DPDT contacts
Contact Switching Current: 1.0A max.
Contact Switching Voltage: 28V max.
Lamp/Audio Duration: 1-30 sec., (1 sec. increments)
Environmental
Ambient Temperature: 0º C to 50º C (32º F to 122º F)
Relative Humidity: 0 to 90% Non-Condensing
Regulatory
Emissions: FCC Part 15
Safety: UL 1950 Can/CSA C22.2 No. 950-95
FTZ: 17TR2100
ETSI: IETS 300330
ITETS: ETS300683
Electrical Specifications - Power supply
Integrated Power Supply with no External Electronics. Primary
Input: 100-120 Vac @50-60 Hz
• 200-240 Vac @ 50-60 Hz
• Primary Power Fuse: 3A, 250 V slow-blow
• Current Draw: 2.0 A peak
• Input Power: 180W
Mechanical
(HxWxD): 145 x 41 x 9 cm (57 x 16.1 x 3.5 in.)
Weight: Primary 12.6 kg (27.5 lbs.)
Secondar
y: 10.6 kg (23.0 lbs.)
Product Code Series (U.S.)
ZAUPMH2: Ultra*Post Primar
y
ZAUPSH2: Ultra*Post Secondar
y
• ZAUP9030-3F: Ultra*Post Secondary – 3ft System
• ZAUP9030-6F: Ultra*Post Secondar
y – 6ft System
ZPCOUNT
: Alar
m Counter
Product Code Series (Europe)
ZAUPML: Ultra*Post Primar
y
ZAUPDUAL: Ultra*Post Primary and Secondary
ZPCOUNT
: Alarm Counter
U.S. Europe
Single
pedestal
Single with
Rangers
Dual
pedestals
Max. ped.
spacing
0.9 m (3’)
1.1 m (3.5’)
1.8 m (6’)
Total exit
coverage
1.8 m (6’)
2 m (6.5’)
3.6 m (12’)
Max. ped.
spacing
0.7 m (2.3’)
1 m (3.2’)
1.6 m (5.3’)
Total exit
coverage
1.6 m (5.3’)
1.7 m (5.6’)
3 m (9.9’)