Specifications

METTLER TOLEDO Weigh Module Systems Handbook
(12/99)14-60
Load Cell Specifications
Rated Capacity of Load Cell 50, 100, 200, 300, 500,
1,000, 2,000, 3,000, 5,000,
10,000 (lb)
25, 75, 100, 200, 500,
1,000, 2,000, 5,000 (kg)
Rated Output 2.0 ± 0.2 mV/V 2.0 ± 0.2 mV/V
Zero Balance ± 1.0% of R.C. ± 1.0% of R.C.
Combined Error Due to Non-
Linearity and Hysteresis
0.03% of R.C. 0.03% of R.C.
Non-Repeatability 0.01% of R.C. 0.01% of R.C.
Temperature Compensation -10° to +40° C
+14° to +104° F
-10° to +40° C
+14° to +104° F
Terminal Resistance
Input: 350
Signal: 350 ±3
Input: 350
Signal: 350 ±3
Excitation Voltage 20 VDC maximum 20 VDC maximum
Insulation Resistance
5 Giga minimum @ 50 VDC 5 Giga minimum @ 50 VDC
Maximum Loads % of R.C. Safe Overload: 150
Ultimate Overload: 300
Safe Side Load: 100
Safe Overload: 150
Ultimate Overload: 300
Safe Side Load: 100
Table 14-39: Load Cell Specifications (Tension Weigh Modules)