Specifications

Chapter 14: Appendices
Appendix 11: Engineering Specifications
(12/99) 14-33
OIML System Specifications
Qty.* Load Cell Capacity
(kg)
System Capacity
(kg)
Cable Length (m) Conduit Fitting (H)ermetic Cell
(P)otted Cell
3 220 660 4.57 1/4-18 NPT H
4 220 880 4.57 1/4-18 NPT H
3 550 1,650 4.57 1/4-18 NPT H
4 550 2,200 4.57 1/4-18 NPT H
3 1,100 3,300 4.57 1/4-18 NPT H
4 1,100 4,400 4.57 1/4-18 NPT H
3 2,200 6,600 4.57 1/4-18 NPT H
4 2,200 8,800 4.57 1/4-18 NPT H
3 4,400 13,200 9.14 1/4-18 NPT H
4 4,400 17,600 9.14 1/4-18 NPT H
3 9,072 27,216 9.14 1/4-18 NPT H
4 9,072 36,288 9.14 1/4-18 NPT H
3 13,608 40,824 9.14 1/4-18 NPT H
4 13,608 54,432 9.14 1/4-18 NPT H
3 20,412 61,236 9.14 1/4-18 NPT H
4 20,412 81,648 9.14 1/4-18 NPT H
*System configurations of five or more modules are possible.
Table 14-23: OIML Weigh Module System Specifications (Flexmount)