Technical data

Chapter 3: Programming and Calibration
General Information
(9/00) 3-5
Configuring JAGXTREME
Terminals With Multiple
Scales and a Summing
Scale
A JAGXTREME terminal can operate with one, two, three or four scales connected. It is
possible to combine analog and DigiTOL scales. The JAGXTREME terminal is
programmed for multiple-scale operation as follows:
1. Determine which scale is currently displayed. The cursor beneath the lower
display will indicate which scale is selected. If a JAGXTREME terminal was
previously programmed as a one-scale terminal, scale A should be displayed.
2. Enter setup mode and access the Scale Interface program block for scale A.
Configure the # INTRNL SCLS parameter in the Scale Type sub-block as 1, 2,
3, 4 or 5, depending on how many scales you will be using. This allows you
to select the next scale (Scale B) from the home position (outside setup mode)
and another scale as a summing scale.
3. Finish configuring and calibrating scale A. (Make sure Add in Sum Y is
selected for a summing scale.)
4. After calibrating scale A, exit from setup.
5. From the home position, press SELECT until scale B appears in the lower
display. Press ENTER to select scale B. The upper display will show weight
from scale B. If no previous calibration exists for scale B, the upper display will
show dashes.
6. Configure and calibrate scale B. Do not change the parameter # INTRNL SCLS
back to 1. Make sure Add in Sum Y is selected for a summing scale.
7. Exit setup.
8. From the home position, press SELECT until the third scale is displayed in the
lower display. Press ENTER to select scale. The upper display will show
dashes.
9. Configure the third scale as the summing scale (select summing as scale
type) if you are only using two scales. Otherwise, configure the remaining
scales, configuring the last one as the summing scale (select summing as
scale type.)
10. Exit setup. You can now select scale A, B, C, D or the summing scale.
If two scales are single channel analog
scales, make sure that the board
address jumper (W3) for the second is
set for B2 (Board 2).
If both scales are MMR (IDNET) scales,
make sure that the board address
j
umper (W4) for the second scale is
installed. The (W5) jumper is removed
on the second scale card.