Home-Run Cable Maximum Length
The maximum cable distance from the PIT Power Supply to the JAGXTREME terminal
POWERCELL PCB depends on the number of POWERCELLs, home-run cable gauge,
and the AC power voltage level. Use the following table to determine the cable gauge
and recommended cable distance:
Home-Run Cable Distance
Number of Cells 20 Gauge
(Feet/Meters)
16 Gauge
(Feet/Meters)
4
6
8
10
12
900/274.32
712/217.018
475/144.78
332/101.19
237/72.24
900/274.32
900/274.32
900/274.32
878/267.61
644/196.29
MMR (IDNET) Base Cable Connections
The maximum recommended cable length for MMR (IDNET) bases is 300 feet (91.44
meters.)
The following diagram describes MMR cell terminal strip wiring.
MMR
(IDNET)
IDNET Adapter Harness
(0900-0284)
JAGXTREME Terminal High
Precision PCB
Base
B B Blue + 32 VDC
C C Gray + 12 VDC
H H Pink Gnd
D D Brown RXD +
A A Green TXD +
F F White RXD -
J J Yellow TXD -
Shield