Technical data

METTLER TOLEDO JAGXTREME Terminal Technical Manual
(9/00) 2-8
UltraRes and DigiTOL Load Cell Connections
The maximum recommended cable length for all DigiTOL bases is 50 feet (15.24
meters). The following diagram describes DigiTOL load cell terminal strip wiring.
JAGXTREME Terminal COM2 or COM4*
Port
DigiTOL NC TXDB
B/P Base
NC RXDB
7 Blue Gnd
1 Red TXD+
4 White NC TXD-
8 Black RXD+
6 Yellow RXD-
5 Green +20V
Shield
Chassis Ground
*When interfacing a DigiTOL or UltraRes base to COM4 (available on the optional Multifunction
PCB), W2 must be set for 20V. Refer to the section entitled JAGXTREME Terminal Jumper and
Switch Settings in this chapter.
Enhanced DigiTOL J-Box Connections
Use the following table to determine the cable gauge and recommended distance
between the JAGXTREME terminal and the Enhanced DigiTOL J-Box.
Cable Gauge Cable Distance
Part Number
6 cond. 24 AWG
Up to 150 feet
(45.72 meters)
510624370
or
14264100A
*6 cond. 20 AWG
Up to 300 feet
(91.44 meters)
510620370