Operating instructions

18
5.3 Dynamic weighing
Dynamic weighing is suitable for the weighing of unstable weighing samples. The mean value of the weighing
results is determined over a specified time period (weighing time). The more unstable the weighing sample,
the longer the selected weighing time.
Requirement
"F dYn A" for automatic start or "F dYn M" for manual start must be activated in the menu (section 4).
Factory setting is a weighing time of 3 seconds (t = 3").
Tare container
Tare:
0/T
key.
Dynamic weighing with automatic start (F dYn A)
Select dynamic weighing with the key. The display shows the symbol ,.
Load weighing sample. As soon as the balance is relatively stable, weighing starts automatically.
During the weighing time, a "count down" runs in the display.
Read off result.
The result of the dynamic weighing is displayed with (= calculated value) and remains in the display
until the weighing sample is removed from the weighing pan or the container.
Notes
The weighing cycle with the same weighing sample can be restarted with the key.
The key can be used to switch between dynamic weighing and normal weighing.
0.00
k
-- 3 --
260.33
g
257.35
g
-- 1 --
0.00
g
g
For weighing goods below 5 g, use dynamic weighing with manual start.