System Configuration Parameters
General
The WESROC Residential LTE Cellular Tank Monitor (RTM) system configuration
parameters can be modified using the WESROC Portable Diagnostic Unit (PDU). These
configuration parameters can also be modified by the WESROC Host system (Host) during
a report.
Parameter List
Base ID: Used to identify a particular RTM device in the Host database.
Min: 000000000001; Max: 999999999999
Default: 99xxxxxxxxxx; Disable: N/A
Primary IP Address: The IP address used to report to the primary Host.
Min: 0.0.0.1; Max: 255.255.255.255
Disable: 0.0.0.0 (Do not report.)
Primary IP Port: The IP port number used to report to the primary Host.
Min: 1; Max: 65535
Disable: 0 (Do not report.)
Secondary IP Address: The IP address used to report to the backup Host.
Min: 0.0.0.1; Max: 255.255.255.255
Disable: 0.0.0.0 (Do not report.)
Secondary IP Port: The IP port number used to report to the backup Host.
Min: 1; Max: 65535
Disable: 0 (Do not report.)
Host Response Timeout: The maximum number of seconds that the RTM will wait for a
response from the Host before sending a data packet retry.
Min: 5; Max: 60
Default: 45; Disable: N/A
Maximum Packet Retries: The maximum number of times that the RTM will retry sending a
data packet to the Host before terminating a report.
Min: 1; Max: 8
Default: 2; Disable: N/A
Report Interval: The number of minutes until the next scheduled report to the Host.
Min: 60 (One Hour); Max: 65535 (45.5 Days)
Default: 10080 (7 Days); Disable: N/A
Low Battery Threshold (mV): The low battery threshold for the RTM system battery.
Min: 2500; Max: 3600
Default: 2808 (78%); Disable: N/A