User`s guide
10
Operational
Depth of Scan Field: 254mm to 559mm (10" to 22")
Scan Speed: 1,250 scan lines per second
Scan Pattern: 25 line omnidirectional
Exit Angle: 12E down off perpendicular of scan window
Indicators: LED: red = good read; green = laser on
Beeper Operation: Selection of 3 tones for “Good Read”
Maintenance Required: Clean window periodically
Decode Capability: Autodiscriminates
System Interfaces: RS232C; Light Pen Emulation; OCIA;
RS422
Print Contrast: 35% minimum reflectance difference
Roll, Pitch, Yaw: 360E, 60E, 60E
Environmental
Storage Temperature: -40EC to 60EC (-40EF to 140EF)
Operating Temperature: 0EC to 35EC (32EF to 95EF)
Humidity: 5% to 95% relative humidity, non-
condensing
Light Levels: Up to 3200 foot candles - works in direct
sun
Ventilation: None required
Shock: 100g for 1ms
ESD: 8 kV IEC 801-2
Contaminants: Protects against dust, falling dirt, and
dripping non-corrosive liquid
Patents Pending