Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc.
TABLE OF CONTENTS INTRODUCTION Manual Scope .......................................................................................................................................................................... 1 Product Overview ..................................................................................................................................................................... 1 Base Kit Components...........................................................................................
TABLE OF CONTENTS SCANNER OPERATION Scan Zone.............................................................................................................................................................................. 27 IR Activation Area (IR LED Output) ........................................................................................................................................ 29 Indicator Descriptions............................................................................................
INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of the MS2221 and the MS2222 StratosS scanner only models. If the MS2221 scanner has been integrated with a scale, please refer to the Scale Addendum for detailed instructions on the appropriate cable connections, communication specifications and calibration procedures required by the scale manufacturer and local Weights and Measures Authorities.
INTRODUCTION BASE KIT COMPONENTS B ASE K IT C OMPONENTS Part # MS2 2 2 x - 1 0 5 N z Description StratosS™ Series Scanner x z 1 Scanner Only, Scale Ready – Compact 2 Scanner Only – Sub-Compact D Diamonex Horizontal Window S Sapphire Horizontal Window 00-02407 MetroSelect® Configuration Guide 00-02034 MS2xxx Stratos Series Configuration Addendum 00-02268 MS2221 / MS2222 StratosS Scanner Installation and User’s Guide Guides also available for download at www.metrologic.com.
INTRODUCTION OPTIONAL ACCESSORIES O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer - Regulated Output: +5.2V @ 2A +12V @ 1A 46-00226 120V United States and Canada 46-00227 220V – 240V Continental European 46-00228 220V – 240V United Kingdom 46-00229 220V – 240V China 46-00230 220V – 240V Australia REPLACEMENT PARTS R EPLACEMENT P ARTS Part # Description Window types (Diamonex and Sapphire) are not interchangeable due to laser safety and/or scanner performance differences.
INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling the StratosS. DO NOT TURN the unit upside down with the platter in place. Figure 1 DO NOT PRESS on the window in the platter or the vertical window frame. Figure 2 PLATTER REMOVAL No hardware or tools are required to remove the platter (see Figure 3). Refer to the Maintenance section of this manual for additional information on platter replacement. See caution statement on page 3.
INTRODUCTION MS2221 / MS2222 SCANNER DESIGN SPECIFICATIONS Design Specifications Operational Light Source: Peak Laser Power: Maximum IR LED Output: Horizontal Depth of Field: Vertical Depth of Field: Scan Speed: No. of Scan Lines: Motor Speed: Min Bar Width: Scan Zone: VLD 650 nm <1.5 mW 50μW per IEC 60825-1 measurement procedure 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code 0 mm - 216 mm (0”- 8.5”) for 0.
BASE MODEL CHARACTERISTICS MS2221 Scanner Components Figure 5. MS2221 Components Components ITEM NO.
BASE MODEL CHARACTERISTICS MS2221 Scanner Dimensions Figure 6. MS2221 Dimensions Connector Panel Figure 7. MS2221 Connector Panel Scale ready MS2221 models supply additional connectors for scale and display communication cabling. The use of these connections is dependent on the specific manufacturer of the scale being integrated.
BASE MODEL CHARACTERISTICS MS2221 Scanner Caution and Serial Number Labels Figure 8. MS2221 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No.
BASE MODEL CHARACTERISTICS MS2222 Scanner Components Figure 9. MS2222 Components Components ITEM NO.
BASE MODEL CHARACTERISTICS MS2222 Scanner Dimensions Figure 10. MS2222 Dimensions Connector Panel Figure 11. MS2222 Connectors Specifications are subject to change without notice.
BASE MODEL CHARACTERISTICS MS2222 Scanner Caution and Serial Number Labels Figure 12. MS2222 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No.
INSTALLATION QUICK INSTALLATION OUTLINE st The following is a quick preview of the steps required for 1 time installations. Each item is discussed in detail later in this section. • • • • • • • • • Determine clearance, ventilation and service access requirements. Determine checkout counter layout taking into account package flow, cable routing and power requirements. Choose the mounting option which provides the best cable/power access and unit stability. Unpack the unit.
INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the box’s content for the following items. • Product Manuals • Power Supply • Communication Cables Figure 13 3. Lift the scanner out of the shipping box by gripping the bottom of the unit on both sides. Important! Do not lift the unit out of the box by gripping the sides of the platter. 4. Carefully remove the shipping foam around the unit.
INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2221 Mounting Diagram Figure 17. MS2221 Mounting Diagram Specifications are subject to change without notice.
INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2222 Mounting Diagram Figure 18. MS2222 Mounting Diagram Specifications are subject to change without notice.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 StratosS application. The scanner must then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee that the StratosS will communicate properly with the host system. Configuration bar codes are located in the MetroSelect Configuration Guide (MLPN 00-02407x) and the MS2xxx Stratos Series Configuration Addendum (MLPN 00-02034x). 1.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual. Figure 19.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full Speed USB StratosS application. The scanner must then be configured to match the host’s USB parameters. Cable installation alone does not guarantee that the StratosS will communicate properly with the host system.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation Mode only. 8. Configure the StratosS for USB Serial Emulation Mode or USB Keyboard Emulation Mode by scanning the appropriate configuration bar codes in the USB section of the MetroSelect Configuration Guide (MLPN 00-02407x) under Low Speed USB. Any low speed USB warnings may be disregarded when utilizing these codes for a Full Speed USB StratosS scanner.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX The following steps describe how to properly install the cables for an IBM 46xx StratosS application. The scanner must then be configured to match the host’s IBM 46xx parameters. Cable installation alone does not guarantee that the StratosS will communicate properly with the host system.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual. Figure 21.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA The following steps describe how to properly install the cables for an OCIA StratosS application. The scanner must then be configured to match the host’s OCIA parameters. Cable installation alone does not guarantee that the StratosS will communicate properly with the host system. Configuration bar codes are located in the MetroSelect Configuration Guide (MLPN 00-02407x) and the MS2xxx Stratos Series Configuration Addendum (MLPN 00-02034x). 1.
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA xx** Specifies international connection. See the Base Kit Components and Optional Accessories section of this guide for a complete listing. See power source caution statement on pages 8 or 11 of this manual. Figure 22.
INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) The following steps describe how to properly install the cables between a secondary Metrologic scanner and the StratosS. The StratosS and the secondary scanner must then be configured to communicate properly. Cable installation alone does not guarantee that the StratosS will communicate properly with the host system and secondary scanner.
INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) † See Aux power notes on page 24 See power source caution statement on pages 8 or 11 of this manual. Figure 23.
INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Base Model Checkpoint Recommended Switch Bank Settings MS2221 SW1 & SW2 switches 1 and 6 set to ON MS2222 SW1 & SW2 switches 1 and 6 set to ON All StratosS models have a connector labeled EAS In on the bottom of the unit.
SCANNER OPERATION SCAN ZONE Figure 26. Checker-Side (13 mil) Figure 27. Horizontal Left/Right (13 mil) Specifications are subject to change without notice.
SCANNER OPERATION SCAN ZONE Figure 28. Horizontal Direct (13 mil) Figure 29. Vertical Direct (13 mil) Specifications are subject to change without notice.
SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosS’s default power save mode† is Dual Action Power Save Mode #2 (see page 35). This power save mode† turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minute intervals. Any movement detected by the IR in the activation area, shown below in grey, will cause the scanner to exit the power save mode.
SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation the StratosS provides audible feedback that indicates the status of the unit and the current scan. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone) plus three volume settings. To change the tone or volume, refer to the Changing the Beeper Tone & Volume section of this manual.
SCANNER OPERATION INDICATOR DESCRIPTIONS Visual Steady Blue When all lasers are active, the blue LED is illuminated. The blue LED will remain illuminated until all lasers are deactivated. Steady Blue and Single White Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. If the white LED does not flash or the scanner does not beep once, then the bar code has not been successfully read.
SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output window near the Metrologic logo on the platter (see figure below). Figure 32. Error Code Display (Optional Product Roll Bar Shown) The following is a list of possible error codes and their meanings. Some errors will require immediate scanner maintenance.
SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 11 SWITCH ERROR – The switch used for volume selection or sleep mode is detected in error (always closed). The condition is self-correcting if possible. If the error persists, return the unit for repair at an authorized service center. The scanning operation can continue with this error active. 21 LASER #1 (VERTICAL) ERROR – The laser in the vertical scanning subsystem denotes a failure.
SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE 34 DESCRIPTION 29 LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNING – The laser in the left vertical scanning subsystem is drawing too little current. The laser is probably not on. This could be the result of a loss of the required set point in memory. Have the unit checked at an authorized service center. 31 MOTOR #1 (VERTICAL) ERROR – The motor in the vertical scanning subsystem denotes a failure.
SCANNER OPERATION POWER SAVE MODES The StratosS has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional information on Power Save Modes. 1. Blink Power Save Mode: Blinks the laser OFF & ON after a configured period of non-use. When the scanner recognizes a bar code it will exit the Blink mode. 2. Laser Off Power Save Mode: Turns the laser OFF after a configured period of non-use. The motor continues to spin allowing for a faster “wake” up time.
SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new tone will be heard followed by a short pause. Two more new tones will be heard signifying the new setting has been stored in memory. The silent (no beep) tone is also selectable. Next Beep Tone ³ 9 9 9 9 7 5 Changing the Beeper Volume Volume levels may be configured using the volume button or incrementally using the following bar code.
SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once (the white LED will remain on for the duration of the beep). The scanner is now ready to scan. POWER-UP TEST MODE When a StratosS scanner is first powered up, it cycles through a number of self-tests before starting normal operation.
MAINTENANCE HORIZONTAL SCAN WINDOW REPLACEMENT After the replacement platter has been installed, remove all protective film from the new platter’s window. The unit will not function properly if the protective film is not removed. Figure 37. Platter/Horizontal Scan Window Replacement * See replacement parts on page 3. † If the platter on the MS2221 is not equipped with a product weight roll bar / lift handle, it can be removed using the same method as shown for the MS2222.
MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (MLPN 46-00232) After the replacement vertical window has been installed, remove all protective film from the window. The unit will not function properly if the protective film is not removed. Figure 38. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the horizontal and vertical output windows will need occasional cleaning. For the glass window: 1.
TROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-4363876 to preserve the limited warranty terms. Symptom Possible Cause(s) Solution All Interfaces No LEDs, beep or motor spin. No power is being supplied to the scanner. Check the transformer, outlet and the power strip. Make sure the power cable is plugged into the scanner. During power up the unit beeps 3 times. A Non-volatile RAM failure.
TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The print quality of the bar code is suspect. Scanner beeps at some bar codes and NOT form others of the same bar code symbology. Check the character length lock. The type of printer and/or the printer settings could be the problem. Check the print mode or change the printer settings. For example change to econo mode or high speed. The aspect ratio of the bar code is out of tolerance.
TROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and host may not be configured for the same interface. Check that the scanner and the host are configured for the same interface. Characters are being dropped. The intercharacter delay needs to be added to the transmitted output. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 0002407x).
DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is, enabled or disabled. The scanner is shipped from the factory preconfigured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every interface does not support every parameter.
DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RSS Expanded Enable Expanded ID “]e0” * RSS Limited Enable OCIA RS232 IBM 46XX USB 9 9 9 9 9 9 9 9 9 9 9 9 RSS Limited ID “]e0” * 9 9 9 9 RSS Limited App ID “01” * 9 9 9 9 RSS Limited Check Digit * 9 9 9 9 9 DTS/SIEMENS DTS/NIXDORF * 9 NCR F 9 NCR S 9 Normal 9 9 9 9 Before Transmit 9 9 9 9 Loudest 9 9 9 9 9 9 9 9 9 9 9 9 Razzberry Tone on Timeout 9 9 9 9 Three Beeps on Timeou
DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Dual Action Power Save Mode #2 * 9 9 9 9 Same Symbol Rescan Timeout: 500 msecs Configurable in 50 msec steps (MAX 6.
DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER OCIA RS232 IBM 46XX USB EAN 128 Enable 9 9 9 9 Enable French Pharma 9 9 9 9 Enable Matrix 2 of 5 Check Digit 9 9 9 9 Enable Hong Kong 2 of 5 9 9 9 9 Enable Alpha Telepen 9 9 9 9 Telepen Convert Lead ‘^L’ to ‘E’ 9 9 9 9 Enable Code 11 Check Digit 9 9 9 9 9 9 Parity Baud Rate DEFAULT Space 9 9600 9 9 8 Data Bits 7 Data Bits * 9 Stop Bits 2 9 RTS / CTS Enabled 9 Message RTS 9 Character RTS * 9 ACK /
DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB STX Prefix 9 9 TAB Prefix 9 9 Metrologic Prefix 9 9 UPC Prefix 9 9 ETX Suffix 9 9 TAB Suffix 9 9 Carriage Return Suffix * 9 9 Line Feed Suffix * 9 9 9 9 UPC Suffix 9 9 st 9 9 nd Start LRC on 2 Byte 9 9 ‘c’ Prefix for UPC 9 9 ‘$’ Prefix for UPC 9 9 Transmit LRC Start LRC on 1 Byte Configurable Prefix Characters 10 avail 9 9 Configurable Suffix Characters 10 avail 9 9
DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Five Digit Redundancy 9 9 9 9 Enable Coupon Code 128 9 9 9 9 Transmit Coupon ‘]C1’ * 9 9 9 9 Group Separator * 9 9 9 9 Coupon Code Can Begin with ’4’ 9 9 9 9 Enable EAN-99 Coupon Code 9 9 9 9 Bookland Supplements 9 9 9 9 French 378/379 Supplements 9 9 9 9 German 434/439 Supplements 9 9 9 9 Convert Bookland to ISBN 9 9 9 9 Bookland 979 Supplements 9 9 9 9 Convert
DEFAULT SETTINGS COMMUNICATION PARAMETERS Default settings for “Aux” interface The secondary scanner and the StratosS series always communicates via RS232.
SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The StratosS scanner terminates to 10-pin modular jacks located on the bottom of the unit. The serial number label indicates the model number and interface of the scanner. EAS Pin Auxiliary RS232 In Function Pin Function 1 EAS In 1 Ground 2 EAS Out 2 RS232 Receive Input DC Power Pin Function 3 RS232 Transmit Output 4 RS232 RTS In 5 RS232 CTS Out 1 12VDC 6-8 2 Ground 9 +5V Out 3 5.
SCANNER AND CABLE TERMINATIONS SCALE READY MS2221 MODELS – ADDITIONAL PINOUT CONNECTIONS There are four additional 10-pin modular jacks located on the bottom of the of the MS2221 StratosS models that may be used for an integrated scale application and the use of a remote display. Please keep in mind that every application is unique. The use of these connections depends on the specifications of the scale’s manufacturer. The following pinouts are for reference only.
SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS The following cables are examples of some of the standard cables that may be shipped with the StratosS scanner. Please keep in mind that every application is unique and the cables received with the StratosS may be custom cables that are not shown below.
SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, MLPN 57-57008x-N-3 Pin 1 2 3 4 5 6-9 Function** No Connect Output from Scanner Input to Scanner No Connect Ground No Connect 9-Pin D-Type Connector RS232 LSO/AUX Cable, MLPN 57-57099x-3 Pin 1 2 3 4 5 6-8 9 10 Function † Signal Ground RS232 from Aux / Secondary Scanner RS232 to Aux / Secondary Scanner RTS from Aux / Secondary Scanner CTS to Aux / Secondary Scanner No Connect +5VDC – Transformer / Direct Shield
REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional.
REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.
REGULATORY COMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist: This device complies with Part 15 of the FCC Rules.
LIMITED WARRANTY The MS2200 StratosS ™ Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS2200 StratosS Series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS2200 StratosS Series scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No.
INDEX A G AC ...................................................................... see power application .................................................................32, 42 audible...........................................................see indicators AUX.......................................................................6, 42, 50 ground.......................................................................50–53 B I beep ..............................................................
INDEX S safety.........................................................................55, 56 Scale ...............................................................................51 scan pattern ......................................................................5 scan speed........................................................................5 scan zone..................................................................27–28 scanner pinouts.................................................................
December 2006 Printed in the USA 00 - 02268B